2013
DOI: 10.1155/2013/278978
|View full text |Cite
|
Sign up to set email alerts
|

Automatic Evaluation of Progression Angle and Fetal Head Station through Intrapartum Echographic Monitoring

Abstract: Labor progression is routinely assessed through transvaginal digital inspections, meaning that the clinical decisions taken during the most delicate phase of pregnancy are subjective and scarcely supported by technological devices. In response to such inadequacies, we combined intrapartum echographic acquisitions with advanced tracking algorithms in a new method for noninvasive, quantitative, and automatic monitoring of labor. Aim of this work is the preliminary clinical validation and accuracy evaluation of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 38 publications
0
8
0
Order By: Relevance
“…Poor reproducibility of head position analysis by digital examination is well known, with correct diagnosis rates ranging from 35 to 39% . We detected an even lower correct diagnosis rate (24%) even though head position was assessed by a senior obstetrician.…”
Section: Discussionmentioning
confidence: 61%
“…Poor reproducibility of head position analysis by digital examination is well known, with correct diagnosis rates ranging from 35 to 39% . We detected an even lower correct diagnosis rate (24%) even though head position was assessed by a senior obstetrician.…”
Section: Discussionmentioning
confidence: 61%
“…where p and r are respectively the precision and recall calculated as 3 Results and discussion Tables 1-3 report the results of the automatic segmentation validation performed by expert operator #1, #2, and #3 respectively. Table 4 shows the values of ALE and RLE calculated according to (7) and 8, respectively. Table 5 summarises the accuracy of the segmentation algorithm as expressed by the F 1 -score.…”
Section: Expert Operator Validationmentioning
confidence: 99%
“…A possible alternative is represented by the employment of dedicated ultrasound (US) techniques, which are radiation-free, portable, less expensive than DXA and available in primary care settings. In fact, bone health assessment is just one out of the several biomedical applications of US systems that have been introduced in the last years because of their mentioned intrinsic advantages over competing technologies [6][7][8][9][10][11][12][13][14][15][16]. In this context, the effectiveness of several quantitative US (QUS) methods for bone health assessment and osteoporosis diagnosis has been recently investigated [17][18][19][20].…”
Section: Introductionmentioning
confidence: 99%
“…In this context, a real‐time tracking algorithm for non‐invasive and automatic monitoring of AoP during the second stage of labor was developed by our research group and tested preliminarily on both a birth simulator and a small number of parturients. The aim of the present study was to introduce an improved version of our algorithm and to evaluate its accuracy in a routine clinical context.…”
Section: Introductionmentioning
confidence: 99%