2003
DOI: 10.1016/s0021-9673(02)01806-x
|View full text |Cite
|
Sign up to set email alerts
|

Automated microgradient system for capillary electrochromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
1

Year Published

2003
2003
2013
2013

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 29 publications
0
9
0
1
Order By: Relevance
“…Kahle et al refined the heart-cut technique they introduced previously [41] for sample injection in monolithic CEC columns and studied the key parameters affecting the injection [42]. The fully automated technique is simple and in addition to sample introduction it also enables gradient elution.…”
Section: Reversed Phase Separationsmentioning
confidence: 99%
“…Kahle et al refined the heart-cut technique they introduced previously [41] for sample injection in monolithic CEC columns and studied the key parameters affecting the injection [42]. The fully automated technique is simple and in addition to sample introduction it also enables gradient elution.…”
Section: Reversed Phase Separationsmentioning
confidence: 99%
“…This may explain the often observed phenomenon that such capillaries have lower plate numbers than capillaries that are homogeneously filled. Several authors have speculated on possible reasons for peak distortion under these circumstances and also presumed changes in the EOF at the interface to be responsible [1,9,22,23]. The fact that the disturbation of the flow occurs in such capillaries at the moment of detection is especially bothersome.…”
Section: Hydrodynamic Pressure Generated By the Eofmentioning
confidence: 99%
“…Several groups have studied the effect of changes in the stationary and the mobile phase composition on the EOF and the chromatographic performance, mostly for capil-laries [1][2][3][4][5][6][7][8][9], but also for microfluidic chips [2,10]. Bello [5] demonstrated how changes in the composition and the pH of the mobile phase influence the EOF.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A variety of different gradient installations have been reported [19][20][21][22][23][24]. International Union of Pure and Applied Chemistry (IUPAC) recommendations on the terminology for analytical capillary electromigration techniques are available [25].…”
Section: Introductionmentioning
confidence: 99%