2022
DOI: 10.1016/j.jhazmat.2021.126893
|View full text |Cite
|
Sign up to set email alerts
|

AuNPs/NiFe-LDHs-assisted laser desorption/ionization mass spectrometry for efficient analysis of metronidazole and its metabolites in water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
15
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 42 publications
0
15
0
Order By: Relevance
“…Several experiments were performed to examine this possibility: i) the XPS spectrum of the Au 3+modified NMOFs was compared to the reported XPS spectrum of AuNPs. [86,87] The results are displayed in Figure 1G. No overlaying band could be detected.…”
Section: Resultsmentioning
confidence: 94%
“…Several experiments were performed to examine this possibility: i) the XPS spectrum of the Au 3+modified NMOFs was compared to the reported XPS spectrum of AuNPs. [86,87] The results are displayed in Figure 1G. No overlaying band could be detected.…”
Section: Resultsmentioning
confidence: 94%
“…The FTIR spectra of the samples are shown in Figure . The broad bands centered at 3346 and 1617 cm –1 are assigned to the O–H stretching modes, bending modes of the interlayer water molecules, and the H-bonded OH groups in LDH, respectively . The intense peaks at 1352 and 781 cm –1 were assigned to the v 3 vibration and the bending modes of CO 3 2– , respectively.…”
Section: Resultsmentioning
confidence: 98%
“…The broad bands centered at 3346 and 1617 cm −1 are assigned to the O−H stretching modes, bending modes of the interlayer water molecules, and the H-bonded OH groups in LDH, respectively. 17 The intense peaks at 1352 and 781 cm −1 were assigned to the v 3 vibration and the bending modes of CO 3 2− , 18 respectively. The bands at 615 and 547 cm −1 are due to M−O vibrations and bending modes in the brucite-like lattice of CoAl−LDH.…”
Section: X-ray Powder Diffraction and Fourier Transform Infraredmentioning
confidence: 99%
“…The mass spectrometry analysis followed our previous method, with minor modifications [ 22 ]. A mixture of DHB and CHCA standards were used for calibration of the mass analyzer, and mixed DHB/CHCA (1:1, w / w ) solution was prepared in 0.1% TFA buffer (ACN/MeOH/water, 70:25:5, v / v / v ) at 20 mg/mL [ 23 ]. The intensity and the global attenuator offset were set to 70% and 15%, respectively, and the repetition rate and frequency were 1000 Hz and 5000 Hz, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The moving distance of the nozzle was 3 mm, the number of spraying cycles was 18, and the spraying density of the optimal matrix on the slice was approximately 0.0025 mg/mm 2 . After matrix spraying, the mixture of DHB/CHCA (1:1, w / w ) solution was dropped on the ITO glass slides where there were no sections of A. lappa roots for molecular weight correction [ 23 ].…”
Section: Methodsmentioning
confidence: 99%