2014
DOI: 10.1016/j.jvoice.2013.08.001
|View full text |Cite
|
Sign up to set email alerts
|

Audio-Perceptual Evaluation of Portuguese Voice Disorders—An Inter- and Intrajudge Reliability Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 31 publications
0
8
0
1
Order By: Relevance
“…The sustained vowel is easier to be obtained and standardized, once it is not affected by the articulation of sound of speech and it is characterized by a relatively static configuration of the laryngeal and supralaryngeal muscles with a minimum variation while producing it (20) . This stability and consistency in the production of the sustained vowel collaborated to a high inter-evaluator concordance (18,20) . A research (21) correlated the task of speech to the reliability found in the perceptual-auditory evaluation of the voice, and the task that presented highest inter-evaluator concordance was the sustained vowel /a/ emission on a regular basis, for the G parameter.…”
Section: Discussionmentioning
confidence: 79%
See 1 more Smart Citation
“…The sustained vowel is easier to be obtained and standardized, once it is not affected by the articulation of sound of speech and it is characterized by a relatively static configuration of the laryngeal and supralaryngeal muscles with a minimum variation while producing it (20) . This stability and consistency in the production of the sustained vowel collaborated to a high inter-evaluator concordance (18,20) . A research (21) correlated the task of speech to the reliability found in the perceptual-auditory evaluation of the voice, and the task that presented highest inter-evaluator concordance was the sustained vowel /a/ emission on a regular basis, for the G parameter.…”
Section: Discussionmentioning
confidence: 79%
“…It was decided to carry out the analysis of the overall degree of deviation (G), for being considered, according to the literature, a robust and reliable parameter (3) . In a previous research (18) , which aimed at characterizing the reliability of intra-and inter-evaluators in the evaluation of all the parameters of the GRBAS using the NS, the G, along with the roughness and breathiness parameters, was what presents higher inter-evaluator concordance. For the evaluation of this research, a five-point NS was used, as proposed by the ICF (16) to quantify a flaw, an impairment, problems, or barriers.…”
Section: Discussionmentioning
confidence: 93%
“…Participants with normal results in the Duration Pattern Test showed significantly greater reliability in the auditory-perceptual assessment than participants with altered results (p=0.003). Another study that described the results of an auditory-perceptual assessment, characterized intra-rater reliability as low for 40% of the judges (26) . A survey focusing on reliability found that more experienced listeners tend to be more consistent in their assessments than untrained evaluators (20) .…”
Section: Discussionmentioning
confidence: 99%
“…181-209) or the American Speech-Language-Hearing Association [13]. They therefore use various procedures and non-standardised definitions of the parameters [30][31][32]. This results in different voice assessment methods hamper the development, objectivity and specificity of therapeutic plans, thus compromising the efficiency and efficacy of intervention strategies.…”
Section: Cross-cultural Adaptation and Translation Of The Grbas And Cmentioning
confidence: 99%