1956
DOI: 10.1103/physrev.102.1071
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: The large double-focusing mass spectrometer recently developed has been used to measure a series of 25 mass doublets. This instrument features a new peak-matching method of measurement which involves the presentation of a portion of the mass spectrum upon an oscilloscope. A group of consistency tests has been performed to prove the correctness of the mass dispersion formula used in calculating mass differences.The measured doublets are sufficient to calculate the mass of C 12 by five different cycles and to al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
1

Year Published

1958
1958
2005
2005

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 87 publications
(18 citation statements)
references
References 7 publications
0
17
0
1
Order By: Relevance
“…Accurate mass tracted into chloroform. ~~~~~~~~i~~ of the chloroform measurements (20) were carried Out On a CEC-21-110B extract gave a residue which had spectroscopic properties double-focussing mass spectrometer. The measurements identical with the product of LiAIH4 reduction of 3. were made by reference to appropriate peaks in the ~~d~~~i with sodium borodeuteride was carried out spectrum of perfluorokerosene (21).…”
Section: Materials A12d Methodsmentioning
confidence: 99%
“…Accurate mass tracted into chloroform. ~~~~~~~~i~~ of the chloroform measurements (20) were carried Out On a CEC-21-110B extract gave a residue which had spectroscopic properties double-focussing mass spectrometer. The measurements identical with the product of LiAIH4 reduction of 3. were made by reference to appropriate peaks in the ~~d~~~i with sodium borodeuteride was carried out spectrum of perfluorokerosene (21).…”
Section: Materials A12d Methodsmentioning
confidence: 99%
“…Mass spectroscopy was done with a CH5-direct probe mass spectrometer (Varian MAT, Bremen, W. Germany) with electron impact ion source, interfaced to a Digital Equipment Company PDP-11/40 computer. Precise mass measurements were made by the peak matching technique (Quisenberg et al, 1956), with perfluoroalkanes as a reference.…”
Section: T H I R O S a W A A N D C P W O L Kmentioning
confidence: 99%
“…13 послед-ние годы к ним добавилась построенная М. Арденне советская маес-спект-рографическая установка с двойной фокусировкой типа Бейнбрид-жа и Иордана, не уступающая по точности установкам Маттауха и Нира 2 . Ниром с сотрудниками в Миннесотском университете в 1956 г. был построен и пущен в ход новый большой масс-спектрометр 3 . Он пред-ставляет собой масс-спектрометр большого размера с двойной фокусиров-кой и с новым методом регистрации ионов.…”
Section: в а-кравцовunclassified