The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
1992
DOI: 10.1016/0304-3991(92)90411-c
|View full text |Cite
|
Sign up to set email alerts
|

Atomic force microscopy imaging of T4 bacteriophages on silicon substrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
64
0

Year Published

1993
1993
2016
2016

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 66 publications
(64 citation statements)
references
References 16 publications
(16 reference statements)
0
64
0
Order By: Relevance
“…The instrument allows simultaneous acquisition of multiple images such as topography, frictional force, and elasticity. The scanner may be operated under ambient laboratory conditions, in vacuum, or in solution (39). The Si 3 N 4 cantilevers were either sharpened microlevers from ThermoMicroscopes (Sunnyvale, CA), with a force constant of 0.1 N͞m, or standard microlevers from Digital Instruments (Santa Barbara, CA) with a force constant of 0.38 N͞m.…”
Section: Methodsmentioning
confidence: 99%
“…The instrument allows simultaneous acquisition of multiple images such as topography, frictional force, and elasticity. The scanner may be operated under ambient laboratory conditions, in vacuum, or in solution (39). The Si 3 N 4 cantilevers were either sharpened microlevers from ThermoMicroscopes (Sunnyvale, CA), with a force constant of 0.1 N͞m, or standard microlevers from Digital Instruments (Santa Barbara, CA) with a force constant of 0.38 N͞m.…”
Section: Methodsmentioning
confidence: 99%
“…This is possibly due to the higher wettability of more concentrated KOH solution on HOPG. The experiments were performed in an environmental chamber containing a homemade AFM 5 head where the relative humidity ͑RH͒ could be controlled. We used a commercial electronic control unit ͑RHK Technology, Rochester Hills, MI͒ and cantilever ͑Digital Instruments, Santa Barbara, CA͒.…”
Section: Methodsmentioning
confidence: 99%
“…AFM is considered more appropriate due to its performing 3D observation in a standard lab environment. As examples, AFM has been applied for morphological studies on hyaluronic acid-collagen/chitosan complex film (Wu et al, 2008), T4 bacteriophage virus particles (Kolbe et al, 1992;Matsko et al, 2001), NIH 3T3 fibroblasts (Kuznetsov et al, 2002) and mouse cardiomyocytes (Kliche et al, 2006). In some applications, AFM was integrated with fluorescence microscope or laser scanning confocal microscope for cell studies (Poole et al, 2004;Zhou et al, 2008).…”
Section: Introductionmentioning
confidence: 98%