2012
DOI: 10.1016/j.jcrs.2011.10.034
|View full text |Cite
|
Sign up to set email alerts
|

Astigmatism correction: Laser in situ keratomileusis versus posterior chamber collagen copolymer toric phakic intraocular lens implantation

Abstract: The stability of the refractive cylinder after toric pIOL implantation was as high as after LASIK. Although predictability in the LASIK group was higher than in the toric pIOL group in eyes with moderate refractive cylinder, the toric pIOL group had higher predictability than the LASIK group in eyes with high refractive cylinder.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
13
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 19 publications
2
13
0
Order By: Relevance
“…These results were consistent with the study by Hasegawa et al,15 who reported a higher predictability of correction with FS-LASIK compared to toric phakic IOL (pIOL) in eyes with moderate refractive cylinder (1.50–2.75 D) compared to high cylinder >3 D, where toric pIOL was found to have better predictability. The authors speculated that this difference was due to difference in the units of refractive cylinder correction since the refractive cylinder power of the T-ICL comes in 0.50 D increments, while the corrective refractive cylinders used in LASIK are in 0.25 D steps 15…”
Section: Discussionsupporting
confidence: 92%
“…These results were consistent with the study by Hasegawa et al,15 who reported a higher predictability of correction with FS-LASIK compared to toric phakic IOL (pIOL) in eyes with moderate refractive cylinder (1.50–2.75 D) compared to high cylinder >3 D, where toric pIOL was found to have better predictability. The authors speculated that this difference was due to difference in the units of refractive cylinder correction since the refractive cylinder power of the T-ICL comes in 0.50 D increments, while the corrective refractive cylinders used in LASIK are in 0.25 D steps 15…”
Section: Discussionsupporting
confidence: 92%
“…The authors found significant regression in sphere but no statistically significant change in cylinder between 1-week and 1-year exams (mean cylinder −0.67±0.54 D at 1 week and −0.63±0.63 D at 1 year). 5 The study was conducted on 48 eyes with preoperative refractive cylinder of −2.74±0.99 D. Similar findings were presented in the study of Hasegawa et al 6 where refractive cylinder remained stable up to 12 months postoperatively in patients with moderate-to-high myopic astigmatism. A small change in refractive cylinder in our study showed statistical significance probably due to the large sample size (compared to other studies); however, it would be interesting to evaluate whether there was a further change beyond the 3-month postoperative visit.…”
Section: Discussionsupporting
confidence: 70%
“… 15 and Hasegawa et al. 16 who reported favorable one-year results with LASIK in cases of moderate to high astigmatism. Katz et al.…”
Section: Discussionmentioning
confidence: 96%