2017
DOI: 10.2174/1871529x16666161027165250
|View full text |Cite
|
Sign up to set email alerts
|

Association Between Waist Circumference and Magnesium and Uric Acid in Indigenous Argentinean Children Living at High Altitude

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
3
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 0 publications
4
3
0
1
Order By: Relevance
“…[26] In another study done on identical twins to nullify the contribution of the genetic factors, SUA was found to be significantly associated with BMI even after adjusting for genetic and family environment factors in both men and women. [27] In one particular study on healthy schoolchildren, waist circumference correlated better with uric acid levels than BMI,[28] which was also noted in our study.…”
Section: Discussionsupporting
confidence: 88%
“…[26] In another study done on identical twins to nullify the contribution of the genetic factors, SUA was found to be significantly associated with BMI even after adjusting for genetic and family environment factors in both men and women. [27] In one particular study on healthy schoolchildren, waist circumference correlated better with uric acid levels than BMI,[28] which was also noted in our study.…”
Section: Discussionsupporting
confidence: 88%
“…[40][41][42] Based on some studies, correlation between WC and SUA is higher than BMI. [43,44] In our study, as presented in table 2, in addition to BMI, WC and WHtR have positive correlation with SUA level, also, the higher BMI patients had higher mean SUA levels.…”
Section: Discussionsupporting
confidence: 60%
“…Fingernail clippings were collected and stored in a sealed plastic bag in a dry and cool condition under room temperature until measurement. Samples were prepared and analyzed based on the following procedure: place samples in a beaker after weighting; add 6 mL nitric acid and 2 mL hydrogen peroxide solution to the breaker and leave it at room temperature overnight; heat the beaker to 180°C on an electronic oven until the samples are dissolved and the fluid turns clear; continue the heating process until the fluid volume reduces to 2 mL; add 5 mL hydrochloric acid to the beaker and continue heating until the fluid volume reduces to 2 mL; stop heating, transfer the fluid to a new volumetric flask, and let it cool naturally; drop deionized water into the volumetric flask until the volume reaches 25 mL; and the fluid is used for measuring Se, Chromium (Cr), [ 19 ] calcium (Ca), [ 20 ] and magnesium (Mg) [ 21 ] concentration by using lame atomic absorption spectrophotometry (ICP-AES optima 8000; PerkinElmer Company, Fremont).…”
Section: Methodsmentioning
confidence: 99%