Assessment of the impact of the electromagnetic field of the catenary system on crack formation in reinforced concrete supports

Abstract: Destruction of reinforced concrete supports is a complex physical and chemical temporary process. The inevitability of destruction is due to the nature of the materials used and the activity of the environment. Centrifuged concrete is an extremely heterogeneous material over the thickness of the products made thereof: in centrifuged structures, several layers are formed over the wall thickness, which differ in their texture and structure. While in operation, the supports are subjected to a complex temperature … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…Scheme for calculating the mutual induction resistance of the catenary system and rails of a one-track section: R1 and R2 are rails, ar is a track width, R1e is an equivalent rail, LB is a loadbearing cable, CW is a contact wire. , the mutual induction resistance between the catenary system and the rails of a one-track section (for Z = 314 rad/s) [19] can be calculated using the following formula: 5652,908 0, 0628 ln 0, 0314 0, 0493…”
Section: Figmentioning
confidence: 99%
See 1 more Smart Citation
“…Scheme for calculating the mutual induction resistance of the catenary system and rails of a one-track section: R1 and R2 are rails, ar is a track width, R1e is an equivalent rail, LB is a loadbearing cable, CW is a contact wire. , the mutual induction resistance between the catenary system and the rails of a one-track section (for Z = 314 rad/s) [19] can be calculated using the following formula: 5652,908 0, 0628 ln 0, 0314 0, 0493…”
Section: Figmentioning
confidence: 99%
“…In accordance with the recommendations of [19], the last monomial of expression ( 4) can be ignored due to its smallness. Finally, the formula for calculating the mutual induction resistance is written as:…”
Section: Introductionmentioning
confidence: 99%
“…The most current (multi-billion) issue is the reinforcement corrosion in constructions of this type. However, it is only one of many possible defects [1][2][3].…”
Section: Introductionmentioning
confidence: 99%
“…The stability and safety of catenary power supply of electrified high-speed railway lines can be effectively guaranteed by doing a good job in the research of catenary portal structure vibration [3,4]. The portal structure not only bears the dynamic lift force between the pantograph and the contact line, but also bears the axial force transmitted to the strut by the bull foot foundation of the strut [5,6]. The portal structure is subjected to complex and variable loads.…”
Section: Introductionmentioning
confidence: 99%