2000
DOI: 10.1016/s0022-1759(00)00295-7
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of synthetic peptides for hepatitis A diagnosis using biosensor technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
27
0
4

Year Published

2001
2001
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 29 publications
0
27
0
4
Order By: Relevance
“…Of all biosensor types, particular attention should be paid to noncontact OBs that have found an ever-widening application in biology and medicine [54][55][56][57][58][59][60][61][62][63][64][65][66][67][68][69]. They are used in the real-time analyses of protein -protein interactions including the interactions between antigen/antibody, oligonucleotide/ oligonucleotide, protein/lipid, hormone/receptor and, also, drug/receptor -with the latter interactions being widely used for drug design and drug testing.…”
Section: Obsmentioning
confidence: 99%
See 1 more Smart Citation
“…Of all biosensor types, particular attention should be paid to noncontact OBs that have found an ever-widening application in biology and medicine [54][55][56][57][58][59][60][61][62][63][64][65][66][67][68][69]. They are used in the real-time analyses of protein -protein interactions including the interactions between antigen/antibody, oligonucleotide/ oligonucleotide, protein/lipid, hormone/receptor and, also, drug/receptor -with the latter interactions being widely used for drug design and drug testing.…”
Section: Obsmentioning
confidence: 99%
“…The advantage of the biosensor system as regards HBsAg revelation in sera lies in rapid (within 5-8 min) detection of the antigen and the repeated usage of the biochip. The same approach was taken for the revelation of antibodies to synthetic peptides, for modelling the antigenic determinants of hepatitis A virus [67] and herpes virus [68], as well as for the revelation of oncological markers [69] and for monitoring of patients with Goodpasture's diseases [76].…”
Section: Biomolecular Analysis (Bia) Of Complex Formation By Use Of Omentioning
confidence: 99%
“…Cita-se o trabalho realizado por Gómara e colaboradores 52 , onde utiliza-se um biossensor comercial (BIACORE 1000, Biacore AB, Uppsala) para detecção do vírus da hepatite A (HAV), através da imobilização de peptídeos sintéticos (VP3) com carbodiimida. Os resultados demonstraram alta eficiência analítica e um potencial clínico no diagnóstico da hepatite A. Este dispositivo mostrou ser uma ferramenta poderosa para rastreamento clínico, de fácil uso, rápido e confiável.…”
Section: Aplicações Biológicas E Clínicasunclassified
“…Different pH values (ranging from 5 to 7.4, depending on the pI of the synthetic peptide) and different peptide concentrations (ranging from 100 to 300/~M in 10 mM acetate buffer) were assayed in order to optimise the signal for capture of antibodies. Finally, immobilization was performed at 25 ~ and at a flow rate of 10/zl min -1 in HBS as a running buffer following the procedure previously described [14].…”
Section: Surface Plasmon Resonance (Spr) Analysismentioning
confidence: 99%