2011
DOI: 10.1017/s146039691100029x
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of set-up discrepancies using daily portal imaging during radiotherapy treatment for patients with spine and bone metastases

Abstract: It is well established that patients with bone metastases get good pain relief from radiotherapy. The aim of treatment is to achieve maximum pain relief with minimum morbidity. Accuracy and reproducibility of the patient's position are fundamental to the successful delivery of radiation therapy. It has been recognised for many years, that the accuracy of patient positioning will improve the success of radiation treatment. A previous study carried out in the department showed that the use of only a single tatto… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 30 publications
2
1
0
Order By: Relevance
“…Young and Blyth also found an increased incidence of images within 5 mm tolerance for multiple marks (45%) compared to a single skin mark set-up (36%) for bony and spinal treatment sites. 6 Deviations over 15 mm are significantly reduced using multiple skin marks, with less than 1% of images from Group 2 falling beyond this threshold, a similar finding to Young and Blyth. 6 Clinically, it is important to reduce the incidence of such large gross deviations, particularly when using a hypofractionated schedule.…”
Section: Discussionsupporting
confidence: 72%
See 2 more Smart Citations
“…Young and Blyth also found an increased incidence of images within 5 mm tolerance for multiple marks (45%) compared to a single skin mark set-up (36%) for bony and spinal treatment sites. 6 Deviations over 15 mm are significantly reduced using multiple skin marks, with less than 1% of images from Group 2 falling beyond this threshold, a similar finding to Young and Blyth. 6 Clinically, it is important to reduce the incidence of such large gross deviations, particularly when using a hypofractionated schedule.…”
Section: Discussionsupporting
confidence: 72%
“…6 Deviations over 15 mm are significantly reduced using multiple skin marks, with less than 1% of images from Group 2 falling beyond this threshold, a similar finding to Young and Blyth. 6 Clinically, it is important to reduce the incidence of such large gross deviations, particularly when using a hypofractionated schedule. Errors of this magnitude could result in geographic miss of the target, resulting in an excessively high dose to normal tissues, potentially increasing toxicity and reducing the efficacy of treatment.…”
Section: Discussionsupporting
confidence: 72%
See 1 more Smart Citation