1976
DOI: 10.1016/s0001-2998(76)80004-9
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of intrarenal perfusion with radioxenon:A critical review of analytical factors and their implications in man

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
14
0

Year Published

1979
1979
2003
2003

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(15 citation statements)
references
References 48 publications
1
14
0
Order By: Relevance
“…10 Because blood flow is registered as milliliters per 100 grams per minute with this method, no further adjustment for kidney size or body size is necessary. This method requires injection of the tracer directly into the renal artery, which we accomplished in potential kidney donors at the time of the renal arteriogram that is required for kidney donation.…”
mentioning
confidence: 99%
“…10 Because blood flow is registered as milliliters per 100 grams per minute with this method, no further adjustment for kidney size or body size is necessary. This method requires injection of the tracer directly into the renal artery, which we accomplished in potential kidney donors at the time of the renal arteriogram that is required for kidney donation.…”
mentioning
confidence: 99%
“…There are, however, further objections to justifying the technique even on empirical grounds. The interlobular artery supplies branches to glomeruli in the juxtamedullary region before supplying the glomeruli of the outer cortex, yet auto radiographic studies in animals using 85krypton imply that the outer cortex is perfused first and then the juxtaglomerular region (Thorburn, Kopald, Herd, Hollenberg, O'Marchoe & Barger, 1963;Hollenberg, Mangel & Fung, 1976 (Glass & de Garetta, 1971). Measurements derived from the second component vary inversely with those derived from the first component in results from normal kidneys and measurements from the first component correlate with cortical flow as assessed by a technique using microspheres (Slotkoff, Logan, Jose, D'Avella & Eisner, 1971).…”
Section: Gas Washout Methodsmentioning
confidence: 99%
“…15 The 133 Xenon washout curves were analyzed as described earlier. [15][16][17][18] In brief, after subtraction of background radiation, the disappearance of 133 Xenon from the kidney, measured by an extracorporeal gamma-probe, is analyzed mathematically by means of a 2-phase exponential decay. Occasionally, a monophasic decline in activity is observed and the curve analyzed accordingly.…”
Section: Intra-arterial 133 Xenon Washout Techniquementioning
confidence: 99%
“…The MRBF is calculated as the weighted average of the fast and the slow components. 18 All analyses were performed with the use of Prism 3.0 software.…”
Section: Intra-arterial 133 Xenon Washout Techniquementioning
confidence: 99%