Assessment of Ecological Efficiency and Energy Efficiency of Foam Use at the Construction Industry Enterprises by Emissions Cleaning Process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…The process of shielding dust particles with a foam layer is characterized by the efficiency E ef(2) -n which value depends mainly on the properties of the foam and the speed of the meeting of the dust particles with the foam bubbles. Taking into account the results of the experimental and theoretical studies presented in [14,15] with respect to the foam layer the quantity E ef(2)-dr is determined by the formula:…”
Section: Discussionmentioning
confidence: 99%
“…The process of shielding dust particles with a foam layer is characterized by the efficiency E ef(2) -n which value depends mainly on the properties of the foam and the speed of the meeting of the dust particles with the foam bubbles. Taking into account the results of the experimental and theoretical studies presented in [14,15] with respect to the foam layer the quantity E ef(2)-dr is determined by the formula:…”
Section: Discussionmentioning
confidence: 99%
“…3010 dust particles with certain bubbles of foam layer, which could be described with the following dependence: (1) where Е eff(1)-dr -is the efficiency of capture and return of dust particles by the foam layer into the stream of technological raw material under the influence of inertia forces; Е eff(2)-dris the efficiency of elastic interaction (repulsion) of dust particles with foam bubbles; Е eff(3)-dr -is the efficiency of capture of dust particles by foam bubbles under the influence of electric forces.…”
Section: Spbwosce-2016mentioning
confidence: 99%
“…Analysis of experimental data [8] allowed to obtain the dependence of efficiency of capture of dust particles under the influence of electrical forces which we use in calculation in relation to foam method in using foam layer: (3) where q 0 -is electrical mass per charge unit of foam, Kl/m. It should be noted that for artificial electrilization the value of electrical mass per charge unit q 0 depends on the method of foam recharging and potential value [1].…”
Section: Spbwosce-2016mentioning
confidence: 99%
See 1 more Smart Citation
“…However, the need to solve a complex of tasks dealing with dynamics of air pollution control becomes more topical every year. This is due to the factors of material and physical pollution in the current context of urban development which are the most concentrated in the air basin of their territories [1, 2,3]. The toxic components (nitrogen oxides, carbon monoxide, sulfur oxides, benz(a)pyrene, particles of ash and sootflakes) of exhaust and effluent gases of power units of plants, as well as public and domestic power units have a particular negative effect [4].…”
Section: Introduction (Topicality)mentioning
confidence: 99%