2008
DOI: 10.1007/s00586-008-0769-8
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of different screw augmentation techniques and screw designs in osteoporotic spines

Abstract: This is an experimental study on human cadaver spines. The objective of this study is to compare the pullout forces between three screw augmentation methods and two different screw designs. Surgical interventions of patients with osteoporosis increase following the epidemiological development. Biomechanically the pedicle provides the strongest screw fixation in healthy bone, whereas in osteoporosis all areas of the vertebra are affected by the disease. This explains the high screw failure rates in those patien… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
160
0
13

Year Published

2010
2010
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 198 publications
(180 citation statements)
references
References 38 publications
7
160
0
13
Order By: Relevance
“…PMMA bone cement has been used in revision of failed uncemented femoral components of total hip arthroplasty (10), enforcement of transpedicle screw fixation in patients with osteoporosis for decades (2). Despite of its rare complication such as bone cement leakage and pulmonary embolism, more clinical application of PMMA can be seen in vertebroplasty of osteoporotic vertebral fractures in recently years (30).…”
Section: Resultsmentioning
confidence: 99%
“…PMMA bone cement has been used in revision of failed uncemented femoral components of total hip arthroplasty (10), enforcement of transpedicle screw fixation in patients with osteoporosis for decades (2). Despite of its rare complication such as bone cement leakage and pulmonary embolism, more clinical application of PMMA can be seen in vertebroplasty of osteoporotic vertebral fractures in recently years (30).…”
Section: Resultsmentioning
confidence: 99%
“…Augmentation of screws does help to diminish the risk of screw loosening [3,5,8], but it is unclear whether it prevents cage subsidence as well. As thoracic and higher lumbar transpedicular screws are introduced with minor convergence, cement, which is injected through the screws, does not reach the central part of the endplates where endplates provide the least resistance to subsidence [18].…”
Section: Discussionmentioning
confidence: 99%
“…Most experiments are done with pull-out test to investigate the fixation strength of single pedicle screws [4,[11][12][13][14][15][16][17][18][19][20][21] or other posterior fixation systems [16,20,22]. Sometimes screws are also tested with so-called toggling tests where cyclic bending moments are used [23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%