2014
DOI: 10.1016/j.chroma.2014.05.057
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of a new method for the analysis of decomposition gases of polymers by a combining thermogravimetric solid-phase extraction and thermal desorption gas chromatography mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
48
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 87 publications
(52 citation statements)
references
References 45 publications
0
48
0
2
Order By: Relevance
“…This is not surprising because the calibration curves for PE in soil achieved an R 2 factor of around 0.99 (Fig. 4) and the relative error of the method is known from former investigations to be~10% (Duemichen et al, 2014).…”
Section: Verifying the Pe Calibrationmentioning
confidence: 73%
See 3 more Smart Citations
“…This is not surprising because the calibration curves for PE in soil achieved an R 2 factor of around 0.99 (Fig. 4) and the relative error of the method is known from former investigations to be~10% (Duemichen et al, 2014).…”
Section: Verifying the Pe Calibrationmentioning
confidence: 73%
“…Most of our work has focused on the material characterization and the material stabilization at high temperature or in oxidizing atmosphere. Recently we introduced a new, advantageous combination of techniques, which was developed for the semi-quantitative analysis of polymer decomposition (Duemichen et al, 2014(Duemichen et al, , 2015. In this method, the advantages of TGA were combined with the advantages of GCeMS, coupled by a solid-phase extraction process.…”
Section: Generalmentioning
confidence: 99%
See 2 more Smart Citations
“…Auf das zusätzliche Potenzial, die Anforderungen und die Vorteile einer Kopplung von TG mit einer Thermosorption/-desorptions-GC-MS gegenüber der TG-MS bzw. TG-FTIR-MS bei der Untersuchung des thermischen Abbaus von Polymeren wird ausführ-lich und vergleichend in neuen Studien eingegangen (Dümichen et al 2014(Dümichen et al , 2015b. In diesen Untersuchungen wurden die Verbrennungsgase auf kommerziell erhältlichen, üblicherweise zur Headspaceanalyse verwendeten Polydimethylsiloxan-be schichteten Magnetrührstäben (Twister ® ) sorbiert und in einem anschließenden Schritt mit der zugehörigen Thermodesorptionseinheit durch GC-MS analysiert.…”
Section: Analyse Mittels Raman-spektroskopieunclassified