2015
DOI: 10.1016/j.rser.2015.07.087
|View full text |Cite
|
Sign up to set email alerts
|

Assessment and mathematical modeling of energy quality parameters of grid connected photovoltaic inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 18 publications
0
10
0
Order By: Relevance
“…1100, the power quality is characterised as: "The idea of powering and grounding particular sensitive equipment in a matter that is appropriate for the functioning of that equipment" [41]. PQ issue might cause harm or inappropriate functioning of equipment connected to the grid along with end-user equipment [42]. Power quality turbulences associated to both current and voltage like poor voltage regulation, excessive harmonics current overloading in line, load unbalancing, deteriorated power factor (PF), unnecessary neutral current, sag, swell, voltage flicker short interruption, notch and spike worsen the excellence of power delivered.…”
Section: B Choice Of Pq Phenomena and Indices For Representationmentioning
confidence: 99%
See 1 more Smart Citation
“…1100, the power quality is characterised as: "The idea of powering and grounding particular sensitive equipment in a matter that is appropriate for the functioning of that equipment" [41]. PQ issue might cause harm or inappropriate functioning of equipment connected to the grid along with end-user equipment [42]. Power quality turbulences associated to both current and voltage like poor voltage regulation, excessive harmonics current overloading in line, load unbalancing, deteriorated power factor (PF), unnecessary neutral current, sag, swell, voltage flicker short interruption, notch and spike worsen the excellence of power delivered.…”
Section: B Choice Of Pq Phenomena and Indices For Representationmentioning
confidence: 99%
“…Distributed generation has a significant role concerning the quality of power since the operational events of renewable energy affect the PQ of DNs. Specifically, large current fluctuations all through outage and synchronization of RES based DGs may result in substantial voltage transients [42]. The complete PQ performance of the distribution network is further exacerbated with high penetration of renewable energy along with non-linear loads at the same time [43].…”
Section: B Choice Of Pq Phenomena and Indices For Representationmentioning
confidence: 99%
“…The power quality analysis of DG output power owning to the applied active IDMs has been carried out in [16]- [25], [28], [29]. Reference [16] has claimed that the ratio of the injected reactive power disturbance (ΔQ) to the active power output (P DG ) in AFD must be kept within the range of [-0.95%, 4.11%] to satisfy the standard requirements for a sample GCPVS.…”
Section: Introductionmentioning
confidence: 99%
“…Otherwise, THD I would be unacceptable in some multiple DGs scenarios. Reference [28] has studied the power quality assessment of ten string inverters, connected to the Brazilian power grid. The power analyzer has been employed to measure THD I and voltage THD (THD V ) as well as power factor with a few loadings.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation