2007
DOI: 10.1038/nbt1277
|View full text |Cite
|
Sign up to set email alerts
|

Artificial reporter gene providing MRI contrast based on proton exchange

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
428
0
2

Year Published

2009
2009
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 376 publications
(431 citation statements)
references
References 15 publications
1
428
0
2
Order By: Relevance
“…Proof of concept was recently reported. 47 However, all these novel developments, although very promising in terms of contrast improvement, raise a lot of questions about toxic and immunologic side effects. For these reasons, the standard, safe CAs studied here and clinically approved for i.v.…”
Section: Discussionmentioning
confidence: 99%
“…Proof of concept was recently reported. 47 However, all these novel developments, although very promising in terms of contrast improvement, raise a lot of questions about toxic and immunologic side effects. For these reasons, the standard, safe CAs studied here and clinically approved for i.v.…”
Section: Discussionmentioning
confidence: 99%
“…After injection into mice carrying s.c. xenograft tumors, these strains, in conjunction with bioluminescent 3D optical tomography combined with micro-CT scanning, were used to visualize the malignant growths. To reach deeper tissues in patients and even multiplex output, next-generation systems could be extended to the expression of protein-based contrast agents (45,(54)(55)(56). Using heme-binding proteins and other reporters from functional magnetic resonance imaging, future applications could possibly report from deeper tissue, using orthologous reporters for greater information retrieval.…”
Section: In Vivo Diagnosticsmentioning
confidence: 99%
“…k 1c ϭ 1/T 1c ϩ k ca [18] k 1d ϭ 1/T 1d ϩ k da [19] k 2a ϭ 1/T 2a ϩ k ab ϩ k ac ϩ k ad [20] k 2b ϭ 1/T 2b ϩ k ba [21] k 2c ϭ 1/T 2c ϩ k ca [22] k 2d ϭ 1/T 2d ϩ k da [23] T 1i and T 2i are the longitudinal and transverse relaxation times of pool i, i is the lifetime of protons in pool i, a is the frequency of the irradiation pulse, i is the Larmor frequency of pool i, 1 Inserting Eq. 24 into Eq.…”
Section: Appendixmentioning
confidence: 99%
“…Diamagnetic and paramagnetic chemical exchange saturation transfer (PARACEST) (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12) agents have many possible medical and biologic applications, including the measurement of tissue pH based on the pH dependence of the exchange rate of amide protons with bulk water protons (13)(14)(15), the measurement of tissue temperature using the linear dependence of the bound water chemical shift on temperature (16,17), enzymatic activity (18), and metabolite levels (19)(20)(21). The CEST detection sensitivity (or CEST effect) is defined as the change in the bulk water signal intensity of the agent solution following irradiation of the exchangeable protons.…”
mentioning
confidence: 99%