1991
DOI: 10.1021/ac00022a021
|View full text |Cite
|
Sign up to set email alerts
|

Argon inductively coupled plasma mass spectrometry with thermospray, ultrasonic, and pneumatic nebulization

Abstract: 9) Patel, Ragina M.; Benson, James R.; Hometchko, DavM. LC-QC (IO) Abidi, S. L. J . Liq. Chroma?&. 1989, 72(4). 595-611. (11) Krstulovic. A. M.; Brown, P. R. Reversed-Phase Hlgh-Performance Liquid Chromtogrephy, Theory, Practice and B b m k l Appllca-Nons; John Wiley and Sons: New York, 1982; Chapter 6. (1) Hao. Zhang; Cooney, Davld A.; Hartman, Nei l R.; Perno, Carlo F.; Frid-2155-2156. 1990, 8 (2), 152-158. lend, Amdd; DeVIco, Anthony L.; Sarngadharan, M. G.; Broder, Samu-(2) Mack, D. 0.; Reed, V. L.; Smith,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0
1

Year Published

1996
1996
2014
2014

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(27 citation statements)
references
References 46 publications
0
26
0
1
Order By: Relevance
“…With two exceptions, the instrumentation used in this work is similar to that described elsewhere [24,25,55]. First, in addition to the original mechanical pump (33-m 3 /h) used for the Ar ICPMS interface [55], a second mechanical pump (a 96-m 3 /h pump, Edward High Vacuum International, Wilmington, MA) was installed on a separate port for the ICPMS interface.…”
Section: Methodsmentioning
confidence: 99%
“…With two exceptions, the instrumentation used in this work is similar to that described elsewhere [24,25,55]. First, in addition to the original mechanical pump (33-m 3 /h) used for the Ar ICPMS interface [55], a second mechanical pump (a 96-m 3 /h pump, Edward High Vacuum International, Wilmington, MA) was installed on a separate port for the ICPMS interface.…”
Section: Methodsmentioning
confidence: 99%
“…Porous [161,162] as well as non-porous [163,164] fluoropolymer membrane is set up at the chamber exit. A sweep argon stream is Eliminado: Figure 13 introduced to remove the solvent vapour.…”
Section: Desolvation Systemsmentioning
confidence: 99%
“…This improvement is due to the increased analyte transport to the plasma resulting from the initial production of a dense aerosol with smaller droplets than those from pneumatic nebulizers (PNs) (32,33). When both USN and PN are used with desolvation, the USN improves detection limits by a factor of 3-8 over the PN (34). Therefore, an ultrasonic nebulizer is chosen as an alternative for the CE-ICP-MS interface.…”
Section: Introductionmentioning
confidence: 99%