Aqueous Humor Dynamics of the Brown-Norway Rat

Abstract: PurposeThe study aimed to provide a quantitative description of aqueous humor dynamics in healthy rat eyes.MethodsOne eye of 26 anesthetized adult Brown-Norway rats was cannulated with a needle connected to a perfusion pump and pressure transducer. Pressure-flow data were measured in live and dead eyes by varying pump rate (constant-flow technique) or by modulating pump duty cycle to hold intraocular pressure (IOP) at set levels (modified constant-pressure technique). Data were fit by the Goldmann equation to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
27
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(30 citation statements)
references
References 40 publications
(88 reference statements)
3
27
0
Order By: Relevance
“…C was 22 ± 4 nl/min/mmHg at resting ICP, which is indistinguishable ( p = 0.68) from reported values in rats not subjected to cerebral ventricle cannulation (Ficarrotta et al . ). C was 13 ± 3 nl/min/mmHg at high ICP, a reduction of 41.0 ± 13.4% ( p < 0.01).…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations
“…C was 22 ± 4 nl/min/mmHg at resting ICP, which is indistinguishable ( p = 0.68) from reported values in rats not subjected to cerebral ventricle cannulation (Ficarrotta et al . ). C was 13 ± 3 nl/min/mmHg at high ICP, a reduction of 41.0 ± 13.4% ( p < 0.01).…”
Section: Resultsmentioning
confidence: 97%
“…The conventional outflow facility ( C ), or hydraulic conductance, of the eye was measured using a modified constant‐pressure perfusion technique (Ficarrotta et al . ), in which a control algorithm switched the pump on and off to maintain IOP within 2 mmHg of a user‐specified level. Net outflow ( F ) was calculated for different IOP set points as the product of pump duty cycle ( D ) and pump flow rate ( Fp ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Sensor output was calibrated against a mercury manometer prior to study commencement and verified intermittently thereafter. The calibration procedure and hydrodynamic properties of the system have been described 56 . There is a pressure drop between the sensor and the eye due to the cannula.…”
Section: Methodsmentioning
confidence: 99%