2020
DOI: 10.3390/en13184884
|View full text |Cite
|
Sign up to set email alerts
|

Applying Directly Modified RDFT Method in Active Power Filter for the Power Quality Improvement of the Weak Power Grid

Abstract: The recursive discrete Fourier transformation (RDFT) method can be used for grid voltage phase-locking and harmonic current detection in a shunt active power filter (SAPF). However, in weak power grids such as microgrids, significant errors might occur in the amplitude and phase detection due to grid frequency deviation. In this study, to resolve this problem, a directly modified RDFT (DMRDFT) method is proposed for SAPF weak grid application. Through theoretical analysis, the errors of phase and amplitude det… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 46 publications
0
3
0
Order By: Relevance
“…Further, SI are particularly harmful power quality disturbances. They exert noxious impacts on various components of power systems, like synchronous generators, transformers, power electronic equipment and measurement and control systems [33,[37][38][39][40]. An energy receiver that is especially sensitive to SI is an induction motor.…”
Section: Harmonics Subharmonics and Interharmonicsmentioning
confidence: 99%
“…Further, SI are particularly harmful power quality disturbances. They exert noxious impacts on various components of power systems, like synchronous generators, transformers, power electronic equipment and measurement and control systems [33,[37][38][39][40]. An energy receiver that is especially sensitive to SI is an induction motor.…”
Section: Harmonics Subharmonics and Interharmonicsmentioning
confidence: 99%
“…Interharmonics can disturb the work of power electronic equipment, measurement and control systems [20][21][22], induction motors [23], and light sources, including commonly applied LEDs [24]. At the same time, power quality standards generally do not provide limitations of interharmonics.…”
Section: Introductionmentioning
confidence: 99%
“…Undesirable phenomena due to the interharmonics' occurrence have been discussed in numerous works [20][21][22][23][24][26][27][28][29][30][31][32][33][34][35]. In [26][27][28][29][30], induction motors under voltage fluctuations were analysed.…”
Section: Introductionmentioning
confidence: 99%