Application of the redox potential measurementbased rapid method in the microbial hygienic control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
7
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 5 publications
1
7
0
Order By: Relevance
“…Redox potential was measured by a multichannel reader, a device named 'MicroTester' that monitored redox potential in maximum 64 samples simultaneously (4 blocks of 16 tube test units) and registered values using the manufacturer's Windows-based software (Erdősi et al, 2012). The parameter of decision threshold (DT) was set to be -0.6 mV/min drop rate in this study; this DT has been established previously (Erdősi et al, 2012).…”
Section: Redox Potential Measurement Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…Redox potential was measured by a multichannel reader, a device named 'MicroTester' that monitored redox potential in maximum 64 samples simultaneously (4 blocks of 16 tube test units) and registered values using the manufacturer's Windows-based software (Erdősi et al, 2012). The parameter of decision threshold (DT) was set to be -0.6 mV/min drop rate in this study; this DT has been established previously (Erdősi et al, 2012).…”
Section: Redox Potential Measurement Setupmentioning
confidence: 99%
“…We used a highly selective media, the Z-broth that provides growth support to only P. aeruginosa without any inhibitory substance (Szita et al, 2007). Z-broth has been shown to be a suitable means of accelerated selective P. aeruginosa detection in a study where bacterial growth was detected by impedance measurement (Erdősi et al, 2012). However, impedance/conductance measurements can be in error due to even slight temperature variations and they also demand high hardware cost and skilled personnel.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, it can determine whether or not a unit ensures appropriate hygienic conditions during its activity. In our present work, besides conventional methods, the MicroTester instrument (Erdősi et al, 2012;Reichart et al, 2007), which indicates the growth of bacteria through a change in redox potential, was used.…”
Section: Introductionmentioning
confidence: 99%
“…Correspondingly, the MicroTester instrument enables the use of culture media for the standard microbiological processes as well. The shape of the redox curve is related to different microbial groups that differ from one another; by this means, in certain cases, the method makes it possible for the rough identification of the microbial group (Erdősi et al, 2012).…”
Section: Introductionmentioning
confidence: 99%
“…The instrumental procedure based on redox potential measurement was originally developed for rapid determination of viable count of several microorganisms in water, milk, foods, hygienic samples, etc. (rEichart et al, 2007;Erdősi et al, 2012). The aim of the present work was to develop a protocol for rapid detection of Salmonella by the combination of the redox potential based and real-time PCR methods in a simple time and cost-effective manner.…”
mentioning