2006 IEEE International Vacuum Electronics Conference Held Jointly With 2006 IEEE International Vacuum Electron Sources
DOI: 10.1109/ivelec.2006.1666306
|View full text |Cite
|
Sign up to set email alerts
|

Application of the Multi-Beam Klystrons with Reverse Permanent Magnet Focusing System in RF Systems of the Compact Electron Accelerators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0
1

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 1 publication
0
3
0
1
Order By: Relevance
“…Besides, low injection energy of 15 keV made it possible to supply the electron gun and the klystron from the same high voltage (HV) power supply (high voltage of the multibeam klystron KU-399a [26] used in this linac is 15 kV).…”
Section: Mev Industrial Cw Linacmentioning
confidence: 99%
“…Besides, low injection energy of 15 keV made it possible to supply the electron gun and the klystron from the same high voltage (HV) power supply (high voltage of the multibeam klystron KU-399a [26] used in this linac is 15 kV).…”
Section: Mev Industrial Cw Linacmentioning
confidence: 99%
“…В современных клистронах для формирования электронных сгущений используются многолучевые системы и сложные многорезонаторные группирователи, позволяющие реализовать высокие значения коэффициентов усиления и полезного действия [1][2][3]. Однако при их разработке приходится учитывать фундаментальные ограничения, связанные с нарастающим действием расталкивающих сил пространственного заряда при образовании более плотных электронных сгустков.…”
Section: Introductionunclassified
“…The dimensions of a rectangular cavity a, b, and d were chosen from the conditions that there be no generation of higher-order modes TE 02 and TE 11 (0.6λ rf < a < 0.95λ rf , b < 0.5λ rf , where λ rf = c/ƒ rf ) and the horizontal physical aperture of the accelerator has its maximum value A hor = b/2 -R 0 . A KU-399 klystron (Russia) with P rf.max = 25 kW can be used as a continuous rf power supply [5]. For P rf.max = 6.9 kW, the value used for the Q-factor, and the prescribed dimensions of the cavity, the electric field intensity E max should not exceed 20 kV/cm in order that thermal deformation not detune the cavity [3].…”
mentioning
confidence: 99%
“…Measured dynamic acceptance 4. Computed bunch length for U max = 8.1 MV (nominal value) 5. Computed beam lifetime due to the Touschek effect taking account of multiple scattering.…”
mentioning
confidence: 99%