2017
DOI: 10.1080/22797254.2017.1399087
|View full text |Cite
|
Sign up to set email alerts
|

Application of the empirical line method (ELM) to calibrate the airborne Daedalus-CZCS scanner

Abstract: The present investigation aims at providing a reliable evaluation of the geometric and radiometric accuracy of the airborne Daedalus-Coastal Zone Color Scanner (CZCS), through cal/val techniques. To this aim, on November 2014, we accomplished a remote sensing campaign over the Peligna Valley (Italy). Together with the personnel of the III Nucleo Aereo of the Italian Coast Guard, based at the Pescara Airport, we deployed the Daedalus AA1268EM1 CZCS scanner on board the fixed-wing aircraft type ATR42MP and a ASD… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(17 citation statements)
references
References 31 publications
(72 reference statements)
2
15
0
Order By: Relevance
“…Multiple images were taken normal to the Dulux and Spectralon targets at distances of 3.2 m and 1 m respectively. The target sizes satisfied the recommendations in the literature to be a minimum 3 to 10 times the sensor IFOV [87][88][89][90][91][92][93][94][95][96][97][98]132] to ensure that as many pixels as possible associated with each calibration target were selected [88] and to avoid atmospheric effects [87]. Each Dulux panel and the Spectralon target measured 293 (h) × 210 mm (w) and 127 × 127 mm respectively (with a single multi-step column measuring 30 mm (w) × 120 mm (h)).…”
Section: Camera Calibration Image Acquisitionmentioning
confidence: 68%
See 4 more Smart Citations
“…Multiple images were taken normal to the Dulux and Spectralon targets at distances of 3.2 m and 1 m respectively. The target sizes satisfied the recommendations in the literature to be a minimum 3 to 10 times the sensor IFOV [87][88][89][90][91][92][93][94][95][96][97][98]132] to ensure that as many pixels as possible associated with each calibration target were selected [88] and to avoid atmospheric effects [87]. Each Dulux panel and the Spectralon target measured 293 (h) × 210 mm (w) and 127 × 127 mm respectively (with a single multi-step column measuring 30 mm (w) × 120 mm (h)).…”
Section: Camera Calibration Image Acquisitionmentioning
confidence: 68%
“…However, higher reflectance samples (V3 (nominal reflectance 70%); V4 (75%) and V5 (60%) in Table 15) underestimate measured values. Underestimation of high-albedo surfaces by the EL method has been reported previously [94]. Sample V13, red Granite stone (nom.…”
Section: Comparative Assessment Of Measured and El2 Predicted Reflectmentioning
confidence: 77%
See 3 more Smart Citations