2018
DOI: 10.1016/j.jcms.2018.07.026
|View full text |Cite
|
Sign up to set email alerts
|

Application of the 3D digital ostectomy template (DOT) in mandibular angle ostectomy (MAO)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…36 Zhang et al use a round bur to mark the ostectomy line in their recent article. 37 We, instead, propose the use of ultrasonic technology to perform this specific procedure. The use of ultrasonic technology as a cutting tool in mandibular surgery has a number of advantages over conventional methods: (1) it ensures better control of the ostectomy because of the horizontal parallelism of the cut at the cortical level (both buccal and lingual); and (2) it minimizes possible damage to structures adjacent to the bone because of the inherent characteristics of the ultrasonic cut.…”
Section: Discussionmentioning
confidence: 99%
“…36 Zhang et al use a round bur to mark the ostectomy line in their recent article. 37 We, instead, propose the use of ultrasonic technology to perform this specific procedure. The use of ultrasonic technology as a cutting tool in mandibular surgery has a number of advantages over conventional methods: (1) it ensures better control of the ostectomy because of the horizontal parallelism of the cut at the cortical level (both buccal and lingual); and (2) it minimizes possible damage to structures adjacent to the bone because of the inherent characteristics of the ultrasonic cut.…”
Section: Discussionmentioning
confidence: 99%
“…Since 2013, computer image-guided templates and the 3D digital ostectomy template have been applied to mandibular angle ostectomy to improve the accuracy. [17][18][19][20] The main purpose of using the template was to improve the accuracy of surgical sawing and achieve curved bone resection. However, there have been few cases in these studies (n = 10, respectively), indicating that the template technology has not been widely used.…”
Section: Discussionmentioning
confidence: 99%
“…In this procedure sawn edge of the mandible was not smooth and had to be burred, and many bone blocks produced are difficult to remove. Since 2013, computer image-guided templates and the 3D digital ostectomy template have been applied to mandibular angle ostectomy to improve the accuracy 17–20. The main purpose of using the template was to improve the accuracy of surgical sawing and achieve curved bone resection.…”
Section: Discussionmentioning
confidence: 99%
“…The inferior alveolar nerve was located using a 3D technique and the osteotomy lines were drawn far away from the nerve 9 . With the aid of ostectomy templates, the safety and accuracy were ensured 10,11 . All surgeries were successfully performed by the same surgeon, using a traditional intra-oral approach.…”
Section: Methodsmentioning
confidence: 99%