2012
DOI: 10.4152/pea.201203177
|View full text |Cite
|
Sign up to set email alerts
|

Application of Membrane-Selective Electrodes for the Determination of Naftidrofuryl Oxalate in the Presence of Its Alkaline Degradant in Tablets and Plasma

Abstract: Membrane selective electrodes were used to determine Naftidrofuryl Oxalate (NFL) in presence of its alkaline degradate (I). The membrane selective electrodes include construction of water insoluble ion-association complexes. These are NFL-tetraphenyl borate (NFL-TPB), NFL-reinikate (NFL-R). These complexes are used as electroactive materials, in poly-vinyl chloride (PVC) matrix membrane sensors, for the determination of NFL. The performance characteristics of these sensors, evaluated according to IUPAC recomme… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 6 publications
(5 reference statements)
0
9
0
Order By: Relevance
“…The results reveal that, as ionophore provided high stability to the complexes formed with cationic drug present in solution; thus, the membrane selectivity and sensitivity are substantially enhanced. Thus, in the absence of ionophores as in references [24,25], the lowest slope value is found accompanied by the highest selectivity coefficient values. A higher selectivity coefficient value corresponds with more attack by interfering cations on the electrode membrane.…”
Section: Performance Characteristics Of Nft Sensorsmentioning
confidence: 87%
See 4 more Smart Citations
“…The results reveal that, as ionophore provided high stability to the complexes formed with cationic drug present in solution; thus, the membrane selectivity and sensitivity are substantially enhanced. Thus, in the absence of ionophores as in references [24,25], the lowest slope value is found accompanied by the highest selectivity coefficient values. A higher selectivity coefficient value corresponds with more attack by interfering cations on the electrode membrane.…”
Section: Performance Characteristics Of Nft Sensorsmentioning
confidence: 87%
“…The sulphonated calyx-8-arene-based showed the best Nernstian slope (56.4 and 54.1 mV/decade) and selectivity coefficient values compared to reference [25] that used β-cyclodextrin as ionophore. The host-guest complex is stabilized via an electrostatic interaction between the cationic NFT and anionic sulphonated calyx-8-arene.…”
Section: Performance Characteristics Of Nft Sensorsmentioning
confidence: 99%
See 3 more Smart Citations