2004
DOI: 10.2166/wst.2004.0678
|View full text |Cite
|
Sign up to set email alerts
|

Application of ion-sensitive sensors in water quality monitoring

Abstract: Within the last years a trend towards in-situ monitoring can be observed, i.e. most new sensors for water quality monitoring are designed for direct installation in the medium, compact in size and use measurement principles which minimise maintenance demand. Ion-sensitive sensors (Ion-Sensitive-Electrode--ISE) are based on a well known measurement principle and recently some manufacturers have released probe types which are specially adapted for application in water quality monitoring. The function principle o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
29
0
2

Year Published

2007
2007
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 37 publications
(33 citation statements)
references
References 5 publications
(4 reference statements)
1
29
0
2
Order By: Relevance
“…Ex-situ meters require additional sampling device and proper sample preparation (usually filtration) before measurement itself, which increases the level of complexity of the measuring system and extends the time from sampling to obtain information. The specificity of mentioned measurement methods makes in-situ sensors more favourable due to lower operational and maintenance costs, however they require regular calibration and verification of their indications [21,22].…”
Section: On-line Monitoring For Wastewater Treatmentmentioning
confidence: 99%
“…Ex-situ meters require additional sampling device and proper sample preparation (usually filtration) before measurement itself, which increases the level of complexity of the measuring system and extends the time from sampling to obtain information. The specificity of mentioned measurement methods makes in-situ sensors more favourable due to lower operational and maintenance costs, however they require regular calibration and verification of their indications [21,22].…”
Section: On-line Monitoring For Wastewater Treatmentmentioning
confidence: 99%
“…The use of ion-selective electrodes (ISEs) is feasible for real-time monitoring because they can be used to directly in the medium to be tested. Furthermore, ISEs are both compact and low cost (Kim et al, 2006;2007;2011;2013;Mimendia et al, 2010;Tang et al, 2012;Winkler et al, 2004). However, some concerns remain regarding the stability, repeatability, and selectivity of ISEs when continuous immersion of the electrodes in hydroponic solutions is required, such as that in a continuous, on-line system.…”
Section: Introductionmentioning
confidence: 99%
“…Together with a short response time, this allows total data acquisition times of few seconds. Time and costs for operation and maintenance (O þ M) can also be significantly lower than for ex-situ analyzers (Winkler et al 2004). In-situ sensors however necessitate regular external calibration and quality control.…”
Section: Introductionmentioning
confidence: 99%
“…A cross-sensitivity of 1:100indicates that a concentration of 100 mg/l of the disturbance ion induces a potential difference equal to 1 mg/l of the measurement ion(Winkler et al 2004). Cross-sensitivity depends first on the total concentration of the disturbance ion, corrected by an offset, and then on the variations of that concentration, which requires an additional membrane for constant compensation.Two configurations were used in the pilot plant.…”
mentioning