Application of Evidence InvestigatorTMfor the Simultaneous Measurement of Soluble Adhesion Molecules: L‐, P‐, E‐ Selectins, VCAM‐1, ICAM‐1 in a Biochip Platform

Abstract: The semiautomated Evidence Investigator has been applied to the simultaneous specific measurement of soluble adhesion molecules: L-, P-, E- selectins, VCAM-1, ICAM-1 using a reduced volume of sample. The biochip is the solid support and vessel where the sandwich immunoassay takes place. Signal detection, imaging, data processing, and storage are fully automated. Calibration curves are generated simultaneously for each analyte, with automatic validation against supplied calibration data. These curves are used f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 32 publications
1
8
0
Order By: Relevance
“…The reproducibility and long-term stability are essential for measurements in the multicomponent field using new technologies like biochip array The system turned out to be easy to handle and very stable over a long period of time with mean coefficients of variation of around 10% which is compa rable with those published earlier for the Cytokine and Growth Factors array (2) and recently for the Cell Adhesion Molecule array (8).…”
Section: Resultssupporting
confidence: 52%
“…The reproducibility and long-term stability are essential for measurements in the multicomponent field using new technologies like biochip array The system turned out to be easy to handle and very stable over a long period of time with mean coefficients of variation of around 10% which is compa rable with those published earlier for the Cytokine and Growth Factors array (2) and recently for the Cell Adhesion Molecule array (8).…”
Section: Resultssupporting
confidence: 52%
“…Biochip array technology enables simultaneous detection of multiple cytokines and adhesion molecules in a single sample and provides valuable information relating to each tested analyte and possible associations between analytes in each sample 16,17 . We previously tested single cytokines and adhesion molecules in leukemia patients.…”
Section: Discussionmentioning
confidence: 99%
“…The light signal generated from each of the test regions on the biochip is detected using digital imaging technology and compared to that from a stored calibration curve. The concentration of analyte present in the sample is calculated from the calibration curve 17,18 .…”
Section: Multi-analytical Evaluation Using Biochip Array Technologymentioning
confidence: 99%