2007
DOI: 10.1007/s00216-007-1638-8
|View full text |Cite
|
Sign up to set email alerts
|

Application of enriched stable isotopes as tracers in biological systems: a critical review

Abstract: The application of enriched stable isotopes of minerals and trace elements as tracers in biological systems is a rapidly growing research field that benefits from the many new developments in inorganic mass spectrometric instrumentation, primarily within inductively coupled plasma mass spectrometry (ICP-MS) instrumentation, such as reaction/collision cell ICP-MS and multicollector ICP-MS with improved isotope ratio measurement and interference removal capabilities. Adaptation and refinement of radioisotope tra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
84
0
1

Year Published

2011
2011
2013
2013

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 81 publications
(85 citation statements)
references
References 77 publications
0
84
0
1
Order By: Relevance
“…156 Evans et al quantified Pu, Am and Np in food samples, ranging from cabbage to milk and meat by a combination of ion chromatography, ultrasonic nebulisation and ICP-SFMS. Because of the high sensitivity of sector field instrumentation, detection limits as low as 0.02 pg g À1 (4.6 Â 10 À2 Bq kg À1 ) for 239 Pu, 0.011 pg g À1 (3 Â 10 À4 Bq kg À1 ) for 237 Np and 0.033 pg g À1 (2.45 Â 10 À1 Bq kg À1 ) for 243 Am were obtained. The method described can provide data on plutonium contamination in food within three hours of sample receipt without compromising detection limits or accuracy relative to traditional counting methods.…”
Section: Food and Nutrition Sciencesmentioning
confidence: 99%
See 4 more Smart Citations
“…156 Evans et al quantified Pu, Am and Np in food samples, ranging from cabbage to milk and meat by a combination of ion chromatography, ultrasonic nebulisation and ICP-SFMS. Because of the high sensitivity of sector field instrumentation, detection limits as low as 0.02 pg g À1 (4.6 Â 10 À2 Bq kg À1 ) for 239 Pu, 0.011 pg g À1 (3 Â 10 À4 Bq kg À1 ) for 237 Np and 0.033 pg g À1 (2.45 Â 10 À1 Bq kg À1 ) for 243 Am were obtained. The method described can provide data on plutonium contamination in food within three hours of sample receipt without compromising detection limits or accuracy relative to traditional counting methods.…”
Section: Food and Nutrition Sciencesmentioning
confidence: 99%
“…Lariviere et al used an ICP-SFMS-based method with a separation from alkaline earth elements and obtained a method detection limit of 0.19 pgL À1 for Ra, equivalent to 7 mBq L À1 . 204 ICP-SFMS was used to quantify 239 Pu in faeces 205 207 Fission products in nuclear samples were determined by Pitois et al 208 using capillary electrophoresis coupled to ICP-SFMS. A comparison between ICP-SFMS and quadrupole ICP-MS resulted again in lower limits of detection for sector field instrumentation (4 pg mL À1 for Cs and 7 pg mL À1 for lanthanides) compared to quadrupole ICP-MS (6 ng mL À1 for Cs and 8 ng mL À1 for lanthanides).…”
Section: Geological and Radionuclide Applicationsmentioning
confidence: 99%
See 3 more Smart Citations