2008
DOI: 10.1016/j.apradiso.2007.07.018
|View full text |Cite
|
Sign up to set email alerts
|

Application of commercial glasses for high dose measurement using the thermoluminescent technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…This suggests that the lower loss of TL signal of the S-Ce2, S-Nd3 and S-Mn2 glass samples results from the higher stabilization of trapped charge effects when compared with the RWG. This will help in estimating the doses in case the sample could not be read on time due to some reason [15]. For more information, the 10 samples of the S-Ce2, S-Nd3 and S-Mn2 glass samples were annealed by using a dual step process, and then irradiated with 14 mGy, and the TL signal was read out.…”
Section: Thermoluminescence Propertiesmentioning
confidence: 99%
See 1 more Smart Citation
“…This suggests that the lower loss of TL signal of the S-Ce2, S-Nd3 and S-Mn2 glass samples results from the higher stabilization of trapped charge effects when compared with the RWG. This will help in estimating the doses in case the sample could not be read on time due to some reason [15]. For more information, the 10 samples of the S-Ce2, S-Nd3 and S-Mn2 glass samples were annealed by using a dual step process, and then irradiated with 14 mGy, and the TL signal was read out.…”
Section: Thermoluminescence Propertiesmentioning
confidence: 99%
“…Therefore, knowledge about radiation protection, radiation shielding and radiation measurement is vital. Recently, many authors have studied the application of soda lime glass (standard window glass) as an accidental dosimeter [10][11][12][13][14][15]. Soda lime glass is widely available and this makes it very attractive for use.…”
Section: Introductionmentioning
confidence: 99%
“…In the same respect, other researchers (e.g. Bootjomchai et al, 2014;Jipa et al, 2009;Narayan et al, 2008) who studied various types of glass materials found a large decrease in the TL signal (40-65%) after a few days of storage in dark conditions. However, they considered the entire glow curve in the calculation of the TL response, thus, the contribution of the shallow traps to the thermal fading was also taken into account.…”
Section: Long-term Tl Fading Study With Storage In Dark Conditions and Room Temperaturementioning
confidence: 59%