2012
DOI: 10.5185/amlett.2011.4237
|View full text |Cite
|
Sign up to set email alerts
|

Application Of Bismuth-film Modified Glassy Carbon Electrode For Solid-phase Extraction Of Sudan I

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…Then bismuth layer was deposited electrochemically by immersing the modified electrode into a solution containing 0.1 M acetate buffer solution and 100 μL of bismuth ions, and a negative potential for 100 s was applied. 25 Electrochemical measurements including DPV, clean electrode, cyclic votammetry (CV), and electrochemical impedance spectroscopy (EIS) were performed using an electrochemical analyzer (CHI Inc., Shanghai, China) and a three-electrode system at room temperature. All experiments were carried out at room temperature, and all measurements were replicated three times.…”
Section: Tri(2-carboxyethyl)p H O S P H I N E H Y D R O C H L O R I D...mentioning
confidence: 99%
“…Then bismuth layer was deposited electrochemically by immersing the modified electrode into a solution containing 0.1 M acetate buffer solution and 100 μL of bismuth ions, and a negative potential for 100 s was applied. 25 Electrochemical measurements including DPV, clean electrode, cyclic votammetry (CV), and electrochemical impedance spectroscopy (EIS) were performed using an electrochemical analyzer (CHI Inc., Shanghai, China) and a three-electrode system at room temperature. All experiments were carried out at room temperature, and all measurements were replicated three times.…”
Section: Tri(2-carboxyethyl)p H O S P H I N E H Y D R O C H L O R I D...mentioning
confidence: 99%
“…Almost all methods of determining metal in very small quantities require a considerable amount of time in the pre-concentration stage before measurement. In the DPAdSV method, the pre-concentration stage is shorter, generally less than 1 minute [26][27][28][29]. so the DPAdSV method is very suitable for metal determination in seawater ex-bauxite mines.…”
Section: Introductionmentioning
confidence: 99%
“…The use of nanomaterials and nanotracers in biosensors allows new transduction technology and application of a bismuth layer on glass carbon electrodes to detect heavy metals in samples showing an alternative material to substitute toxic mercury. , The main advantages of bismuth are the high capacity to form fused alloys with metals, which are less affected by dissolved oxygen. However, it fails to detect low amounts of analyte due to its poor conductivity, , but applied multiwall carbon nanotubes–bismuth modified on glassy carbon electrodes showed increased sensitivity in the detection of trace metals.…”
Section: Introductionmentioning
confidence: 99%