2015
DOI: 10.1016/j.snb.2015.03.020
|View full text |Cite
|
Sign up to set email alerts
|

Application of Au cage/Ru(bpy)32+ nanostructures for the electrochemiluminescence detection of K562 cancer cells based on aptamer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(7 citation statements)
references
References 33 publications
(26 reference statements)
0
7
0
Order By: Relevance
“…β-Cyclodextrin-AuNPs were used to load Ru(bpy) 3 2+ for the development of a "signal-on" switch ECL biosensor for the detection of MEAR cells [235]. Ge et al reported an ECL method for the detection of K563 cancer cells based on Au nanocages/Ru(bpy) 3 2+ molecules [236]. Hollow Au nanocages with porous structure and high surface area not only possessed more active sites to load a large amount of Ru(bpy) 3 2+ molecules, but also accelerate the electron communication.…”
Section: Electrochemiluminescence Cytosensorsmentioning
confidence: 99%
“…β-Cyclodextrin-AuNPs were used to load Ru(bpy) 3 2+ for the development of a "signal-on" switch ECL biosensor for the detection of MEAR cells [235]. Ge et al reported an ECL method for the detection of K563 cancer cells based on Au nanocages/Ru(bpy) 3 2+ molecules [236]. Hollow Au nanocages with porous structure and high surface area not only possessed more active sites to load a large amount of Ru(bpy) 3 2+ molecules, but also accelerate the electron communication.…”
Section: Electrochemiluminescence Cytosensorsmentioning
confidence: 99%
“…On the other hand, PtNP-dotted CNTs were implemented on the electrode to immobilize the aptamer, improve the electronic transmission, and provide a large surface area. The K562 cancer cells were detected through the sandwich-type assay with a sensitivity of 500 cells/ml [175]. Several recent studies have been conducted on ECL cytosensors by taking advantage of AuNPs to carry cell recognizer or cell-specific receptors with high electron transfer capability [176, 177].…”
Section: The Functions Of Mnps In Various Biosensor Typesmentioning
confidence: 99%
“…Electrochemiluminescence (ECL) has attracted wide attention and has been applied in multiple domains including biodetecting and biosensing technology. However, finding suitable and stable luminescent materials is a major research problem in the construction of ECL sensors . Among numerous illuminants, Ru­(bpy) 3 2+ is a prevalent luminophore because of its admirable ECL efficiency and favorable stability in aqueous solution and nonaqueous solvents .…”
Section: Introductionmentioning
confidence: 99%
“…6−11 However, finding suitable and stable luminescent materials is a major research problem in the construction of ECL sensors. 12 Among numerous illuminants, Ru(bpy) 3 2+ is a prevalent luminophore because of its admirable ECL efficiency and favorable stability in aqueous solution and nonaqueous solvents. 13 These properties generate preponderances such as demanding minimal amounts of costly or poisonous reagents and simplified experimental design considerations especially in the solid-phase immobilized applications.…”
Section: ■ Introductionmentioning
confidence: 99%