2021
DOI: 10.2214/ajr.20.22812
|View full text |Cite
|
Sign up to set email alerts
|

Application of Adaptive Image Receive Coil Technology for Whole-Brain Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 16 publications
1
16
0
Order By: Relevance
“…By adopting densely overlapped thin wire loops with a special conductive material named a INCA conductor instead of conventional copper loops, AIR coil has gained lightness and flexibility [ 13 , 14 ]. Conventional coil arrays are fixed in rigid housing to avoid damage and maintain critical overlap between loops for delivering the best SNR.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…By adopting densely overlapped thin wire loops with a special conductive material named a INCA conductor instead of conventional copper loops, AIR coil has gained lightness and flexibility [ 13 , 14 ]. Conventional coil arrays are fixed in rigid housing to avoid damage and maintain critical overlap between loops for delivering the best SNR.…”
Section: Discussionmentioning
confidence: 99%
“…Conventional coil arrays are fixed in rigid housing to avoid damage and maintain critical overlap between loops for delivering the best SNR. With an INCA conductor connected to a printed circuit board module, AIR coil was designed to reduce coil–coil mutual inductance and coupling between adjacent loops, achieving high decoupling between coil elements and relaxing coil overlap requirements [ 13 , 14 ]. The major interest of this work was to evaluate how such flexibility and interaction between closely overlapped coil elements of 30-channel AIR Anterior Array coil benefit the image quality in lung imaging, combined with a 40-channel posterior array coil.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The anterior UNIC coil was unable to closely surround the body contour as a semi-flexible product coil would do, which can create spacing between the coils and the subject at the peripheral of the field of view and result in suboptimal receive and B0 shim performances. Yet, owing to the intrinsic decoupling scheme, UNIC is adaptable to semiflexible or flexible RF coils [71][72][73][74] , where soft electronics can be employed. A potential complication in using a flexible UNIC coil is that the subject movement may lead to shim field deformation during image acquisition and results in erroneous B0 shim.…”
Section: Discussionmentioning
confidence: 99%
“…Two client computers use SDK to obtain skeleton data and send it to server-side PC through local Ethernet. All bone data are processed in the server, and then, the fused bone data is transmitted to the Unity3d scene for visualization [20]. Because Kinect has the disadvantage of self-occlusion, it cannot obtain the full picture of human posture.…”
Section: Overall Design Of Whole Body Motion Capture Systemmentioning
confidence: 99%