2021
DOI: 10.3390/ma14102580
|View full text |Cite
|
Sign up to set email alerts
|

Apical Pressure Generated Using Conventional Syringe Irrigation in Immature Teeth—An In Vitro Study

Abstract: This in vitro study aimed to evaluate apical pressure during irrigant delivery with syringe irrigation in immature teeth with an open apical foramen. Conventional syringe irrigation was performed in a 3D-printed immature incisor. A 5 mL syringe combined with 25 G and 30 G cannulas was used. Open-ended and side-vented needle tip designs were assessed. Cannulas were placed at tooth length (TL), TL −1 mm, TL −2 mm, and TL −4 mm. The syringe plunger was moved with a force of 10 N, 20 N, 40 N, and 80 N to simulate … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 26 publications
(44 reference statements)
0
4
0
2
Order By: Relevance
“…Irrigation by syringe was tested in the same setting in another study (Jäggi et al, 2021 ). The apical pressures were dependent on the diameter of the cannula (G25 versus G30), the needle tip design (open‐ended versus side‐vented), the insertion depth (TL, TL—1 mm, TL—2 mm, TL—4 mm) and the applied pressure on the syringe plunger (10 N, 20 N, 40 N, 80 N).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Irrigation by syringe was tested in the same setting in another study (Jäggi et al, 2021 ). The apical pressures were dependent on the diameter of the cannula (G25 versus G30), the needle tip design (open‐ended versus side‐vented), the insertion depth (TL, TL—1 mm, TL—2 mm, TL—4 mm) and the applied pressure on the syringe plunger (10 N, 20 N, 40 N, 80 N).…”
Section: Discussionmentioning
confidence: 99%
“…The generated pressures were recorded at an interval of 10 ms by a high-precision pressure sensor with a metering precision of 0.1% and a response time of ≤0.5 ms within a measuring range of 0-120 mmHg. Negative pressures Data for syringe irrigation were obtained from a previous study (Jäggi et al, 2021).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…auch das Kaliumhypochlorit oder das Kalziumhypochlorit. Ende des 18. Jahrhunderts wurde Kaliumhypochlorit in Frankreich von Herrn C.-L. Berthollet erstmals chemisch hergestellt.…”
Section: Natriumhypochloritunclassified
“…Allerdings sollte auf die schallaktivierte Spülung und hydrodynamische Spülsysteme wie bspw. das RinsEndo (Dürr Dental, Bietigheim-Bissingen, Deutschland) aufgrund hoher Druckspitzen verzichtet werden [18,19]. ▶ Abb.…”
Section: Merkeunclassified