2013
DOI: 10.1016/j.jpha.2012.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode

Abstract: The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode. The effects of pH, scan rates, and concentration of the drug on the anodic peak current were studied. Voltammograms of gemifloxacin in Tris–HCl buffer (pH 7.0) exhibited a well-defined single oxidation peak. A differential-pulse voltammetric procedure for the quantitation of gemifloxacin has been developed and suitably validated wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 23 publications
0
15
0
Order By: Relevance
“…As suggested by Geremedhin et al [42] and Radi et al [43], this phenomenon may be due to the limited adsorption of RB5 dye at the mercury electrode, which resulted from the saturation of the electrode surface. As shown in Figure 8, the first linear region demonstrated its linearity from 2.…”
Section: The Effect Of Pulse Amplitudementioning
confidence: 88%
“…As suggested by Geremedhin et al [42] and Radi et al [43], this phenomenon may be due to the limited adsorption of RB5 dye at the mercury electrode, which resulted from the saturation of the electrode surface. As shown in Figure 8, the first linear region demonstrated its linearity from 2.…”
Section: The Effect Of Pulse Amplitudementioning
confidence: 88%
“…In the last years, electrochemical methods have drawn attention [28][29][30][31], due to their high sensitivity and accuracy, which make them convenient for the qualitative and quantitative analysis of organic compounds contained in pharmaceuticals [32][33][34][35][36]. They are characterized by simple measurements and short times of sample analysis in low cost apparatus, in comparison to chromatographic methods [37][38][39][40]. The most common electrochemical methods include differential pulse (DPV) and cyclic (CV) voltammetry [41][42][43].…”
Section: Introductionmentioning
confidence: 99%
“…Screen-printed electrodes (SPEs), are low cost disposable sensors with a three-electrode configuration (Working, Reference and Counter electrodes), providing in this way a miniaturized electrochemical cell. In literature, their capability on investigating drug formulations with their corresponding metabolites is limited (Radi et al, 2013;Kauffmann et al, 2011). Thus, further studies with different types of phase I reactions and multiple pathways are required to prove the efficient use of SPE in metabolism.…”
Section: Introductionmentioning
confidence: 99%