2016
DOI: 10.1039/c6cc02182d
|View full text |Cite
|
Sign up to set email alerts
|

Anodic electrogenerated chemiluminescence behavior and the choline biosensing application of blue emitting conjugated polymer dots

Abstract: The anodic electrochemiluminescence (ECL) behavior of poly(9,9-dioctylfluorenyl-2,7-diyl) (PFO) dots was studied and applied in oxidoreductase-based ECL biosensing using Chox as the model enzyme.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 34 publications
1
21
0
Order By: Relevance
“…48 Then, they prepared nanocomposite C 60 -PAMAM-PFO, which was formed via electrostatic interaction between the negative charged PFO CPNs and the positively charged C 60 -PAMAM (polyamidoamine) nanoparticles. 49 With this C 60 -PAMAM-PFO nanocomposite in the presence of oxidoreductase, they found the ECL behavior of PFO CPNs was enhanced when H 2 O 2 was used as a coreactant. As a result, this ECL nanocomposite material was used as a biosensor to detect H 2 O 2 using Chox as the model enzyme.…”
Section: Electrochemiluminescent and Chemiluminescent Pdots And Cpnsmentioning
confidence: 93%
“…48 Then, they prepared nanocomposite C 60 -PAMAM-PFO, which was formed via electrostatic interaction between the negative charged PFO CPNs and the positively charged C 60 -PAMAM (polyamidoamine) nanoparticles. 49 With this C 60 -PAMAM-PFO nanocomposite in the presence of oxidoreductase, they found the ECL behavior of PFO CPNs was enhanced when H 2 O 2 was used as a coreactant. As a result, this ECL nanocomposite material was used as a biosensor to detect H 2 O 2 using Chox as the model enzyme.…”
Section: Electrochemiluminescent and Chemiluminescent Pdots And Cpnsmentioning
confidence: 93%
“…[44] Then, PFO dots were applied in oxidoreductase-based ECL biosensing. [45] Chi and co-workersd eveloped many polymers capped with Triton X-100 for better ECL behavior. [39] In all, PDots represent avital part of ECL materials.I tisrecommended that AIE experimentss hould be added to help authors understand if AIECL is active in these systems.…”
Section: Polymer Dots (Pdots)mentioning
confidence: 99%
“…For example, Chen et al. presented the anodic ECL behavior of a water soluble poly(9,9‐dioctylfluorenyl‐2,7‐diyl) (PFO) dots . The PEO dots, which possess a negatively charged surface, are desirable owing to their efficient luminescence, excellent charge carrier mobility and good thermal stability.…”
Section: Quantum Dotsmentioning
confidence: 99%