2004
DOI: 10.1021/ac049499w
|View full text |Cite
|
Sign up to set email alerts
|

Anion-Exchange Displacement Centrifugal Partition Chromatography

Abstract: Ion-exchange displacement chromatography has been adapted to centrifugal partition chromatography. The use of an ionic liquid, benzalkonium chloride, as a strong anion-exchanger has proven to be efficient for the preparative separation of phenolic acid regioisomers. Multigram quantities of a mixture of three hydroxycinnamic acid isomers were separated using iodide as a displacer. The displacement process was characterized by a trapezoidal profile of analyte concentration in the eluate with narrow transition zo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
23
0

Year Published

2006
2006
2017
2017

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 22 publications
(24 citation statements)
references
References 32 publications
(57 reference statements)
1
23
0
Order By: Relevance
“…As the concentration of the effluent is driven by the concentration of the displacer, an increase in the sample mass causes a lengthening of the elution time for each component of the mixture, without affecting the transition zones. This observation is clearly supported by computer simulation [8,14] (http://helios.univ-reims.fr/Labos/UPRESA6013/LSD/ JmnSoft/CpcSim/index.html). Therefore, the aim of this work was to set up a pilot-scale isolation of sinalbin from an aqueous white mustard seeds extract, using a 5 L capacity CPC apparatus, and to prove that SIXCPC is a high performance separation technique on an industrial scale.…”
Section: Introductionmentioning
confidence: 56%
See 4 more Smart Citations
“…As the concentration of the effluent is driven by the concentration of the displacer, an increase in the sample mass causes a lengthening of the elution time for each component of the mixture, without affecting the transition zones. This observation is clearly supported by computer simulation [8,14] (http://helios.univ-reims.fr/Labos/UPRESA6013/LSD/ JmnSoft/CpcSim/index.html). Therefore, the aim of this work was to set up a pilot-scale isolation of sinalbin from an aqueous white mustard seeds extract, using a 5 L capacity CPC apparatus, and to prove that SIXCPC is a high performance separation technique on an industrial scale.…”
Section: Introductionmentioning
confidence: 56%
“…Strong ion-exchange is a specific displacement chromatography mode that was introduced in SIXCPC to purify ionizable molecules such as hydroxycinnamic acids [8], rosmarinic acid [11], or GSLs [10]. Even though the stationary phase in CPC is a liquid, SIXCPC is quite similar to ion-exchange chromatography on solid resins.…”
Section: The General Methodsmentioning
confidence: 99%