Analytical Uncertainty Evaluation of Material Parameter Measurements at THz Frequencies

Abstract: Material parameter extraction algorithms are studied and simplified both for transmission-reflection and transmission-only methods. The simplified relations, which are closed-form in some cases, are analyzed to establish the uncertainty sensitivity coefficients and therefore, to clarify the main uncertainty contributions and reduce the systematic and random errors. Simple closed-form expressions presented in this paper show the sensitivity of the extracted permittivity to each input parameter such as S21 (phas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 22 publications
0
8
1
Order By: Relevance
“…The uncertainty budgets showing the main uncertainty contributions for and at 5/10/15/20 GHz are presented in Table 2 and 3. It can be observed from the results that the combined total standard uncertainty in our proposed technique is smaller than that of the recently published work, where the estimated uncertainty of and in the transmission-only method is 3%-4% and 10%-15%, respectively [23]. For the proposed two-line algorithm, it assumes that the transition and connection between MW connectors and transmission lines are mechanically and electrically identical, while in practical cases they are not likely to be completely the same.…”
Section: S S S Scontrasting
confidence: 57%
See 2 more Smart Citations
“…The uncertainty budgets showing the main uncertainty contributions for and at 5/10/15/20 GHz are presented in Table 2 and 3. It can be observed from the results that the combined total standard uncertainty in our proposed technique is smaller than that of the recently published work, where the estimated uncertainty of and in the transmission-only method is 3%-4% and 10%-15%, respectively [23]. For the proposed two-line algorithm, it assumes that the transition and connection between MW connectors and transmission lines are mechanically and electrically identical, while in practical cases they are not likely to be completely the same.…”
Section: S S S Scontrasting
confidence: 57%
“…Table 1 summarizes the comparison between the proposed extraction method and some reported ones in literature for Substrate Complex Permittivity Measurement. There are several sources of error and uncertainty in the measurement of dielectric characterization, mainly including the fabrication tolerance and the VNA measurement error [23]- [26]. Firstly, one of the main sources of error and uncertainty comes from the fabrication tolerance.…”
Section: S S S Smentioning
confidence: 99%
See 1 more Smart Citation
“…One interesting method that can be used to obtain these parameters is by using calibrated RT simulators fed by experimental data where extensive simulations could be used along with different algorithms [289], [290] to extract material parameters such as the dielectric constant. The experimental data can be collected through simple free space reflection and transmission as well as only transmission measurements using a VNA, though each method has its own related uncertainty to be accounted for when it comes to parameter extraction [291].…”
Section: Challenges and Future Research Directions A Open Issues And Challengesmentioning
confidence: 99%
“…In contrast to the conventional quasi-optical free-space system, the MCK system is compact and self-contained, eliminating the need for bulky mirrors or lenses. MCKs have been successfully utilised for material characterization at millimeter-wave and terahertz frequencies [11]- [13].…”
Section: Introductionmentioning
confidence: 99%