2010
DOI: 10.1016/j.jasms.2010.02.007
|View full text |Cite
|
Sign up to set email alerts
|

Analytical strategy for the molecular weight determination of random copolymers of poly(methyl methacrylate) and poly(methacrylic acid)

Abstract: Molecular weight characterization of random amphiphilic copolymers currently represents an analytical challenge. In particular, molecules composed of methacrylic acid (MAA) and methyl methacrylate (MMA) as the repeat units raise issues in commonly used techniques. The present study shows that when random copolymers cannot be properly ionized by MALDI, and hence detected and measured in MS, one possible analytical strategy is to transform them into homopolymers, which are more amenable to this ionization techni… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
13
0
2

Year Published

2010
2010
2022
2022

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 45 publications
0
13
0
2
Order By: Relevance
“…In the case of MALDI, ionization of the PAMAM species only occurred in a small subset of solvent/matrix combinations that were tested. Such challenges have been noted in the literature . In contrast, GPC gave better results particularly for precursors with a greater mass percentage of PLA (i.e., 90‐DL‐G3Boc , 70‐DL‐G3Boc , 90‐L‐G3Boc , and 70‐L‐G3Boc ).…”
Section: Resultsmentioning
confidence: 88%
“…In the case of MALDI, ionization of the PAMAM species only occurred in a small subset of solvent/matrix combinations that were tested. Such challenges have been noted in the literature . In contrast, GPC gave better results particularly for precursors with a greater mass percentage of PLA (i.e., 90‐DL‐G3Boc , 70‐DL‐G3Boc , 90‐L‐G3Boc , and 70‐L‐G3Boc ).…”
Section: Resultsmentioning
confidence: 88%
“…Solche Experimente zeigen einzelne Polymerendgruppen auf; dagegen gibt das eindimensionale MS‐Spektrum Aufschluss über die Summe der in dem Oligomer an den Kettenenden vorliegenden Substituenten, die auch eine oder mehrere unvollständige oder komplette Monomereinheiten enthalten können. Darüber hinaus kann die MS/MS eingesetzt werden, um Copolymersequenzen zu analysieren und Polymerstrukturen zu differenzieren, wie das in den Abschnitten 2.1 und 2.2 mit ausgewählten Beispielen veranschaulicht wird.…”
Section: Tandem‐massenspektrometrie (Ms/ms)unclassified
“…Only end group analysis was applied to estimate MW of PPSE by controlling the type of end groups 12. Practically, MW and its distribution play a fundamental role in achieving good physical performance and processability of polymer, and therefore their determinations are always the topics in polymer science 14–19. For this reason, it is expected that MW of PPSE should be determined more conveniently and reasonably.…”
Section: Introductionmentioning
confidence: 99%