2014
DOI: 10.1109/tie.2014.2308163
|View full text |Cite
|
Sign up to set email alerts
|

Analytical Method for Pattern Generation in Five-Level Cascaded H-Bridge Inverter Using Selective Harmonic Elimination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
79
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 156 publications
(79 citation statements)
references
References 40 publications
0
79
0
Order By: Relevance
“…The output AC voltage waveform should be sinusoidal-like with low harmonic content. A PWM technique with selective harmonic elimination (SHE) is widely used to control multilevel inverter and produce output voltage with low total harmonic distortion (THD) [24]. …”
Section: A Inverter Output As a Function Of Switching Anglesmentioning
confidence: 99%
“…The output AC voltage waveform should be sinusoidal-like with low harmonic content. A PWM technique with selective harmonic elimination (SHE) is widely used to control multilevel inverter and produce output voltage with low total harmonic distortion (THD) [24]. …”
Section: A Inverter Output As a Function Of Switching Anglesmentioning
confidence: 99%
“…The THD, SUR, and DC link summations obtained by the CM method are presented in Table. II for both with and without the SUR cases. An increase in the THD (2.44%) is observed when the SUR is considered and it can be seen that the SUR is enhanced about 6.69% and the DC sum is decreased 6.37% at an output voltage of 0.7. with (8), (9), and (16), respectively. Having M varied between 0 and 1, the function is minimized.…”
Section: ) Analysis and Comparisonmentioning
confidence: 99%
“…Among the different topologies and structures, owing to some characteristics like modular structure, extendibility and electromagnetic compatibility, cascaded H-bridge inverters are the most popular [8]. Different switching techniques and control algorithms are employed to control these inverters [9]- [12]. In most of these methods, the main purpose is harmonic reduction in generated output voltage.…”
Section: Introductionmentioning
confidence: 99%
“…In [14]- [16] fundamental structure have been developed but number of switches and voltage rating of switches are high. A new topology is presented in [17] and three algorithms have been explained that reduces the number of components used. But here the variety of dc sources increases.…”
Section: Introductionmentioning
confidence: 99%