2008
DOI: 10.1016/j.aca.2007.11.031
|View full text |Cite
|
Sign up to set email alerts
|

Analytical artefacts in the speciation of arsenic in clinical samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
44
0
1

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 66 publications
(48 citation statements)
references
References 26 publications
3
44
0
1
Order By: Relevance
“…There have however, been several reports of their presence in urine (Mandal et al, 2001;Valenzuela et al, 2005), although the analytical quality of these data has been questioned Slejkovec et al, 2008). It is worth noting that most studies on arsenic urine metabolites have failed to detect these reduced methylated species despite specific efforts to do so (e.g.…”
Section: Metabolismmentioning
confidence: 99%
See 1 more Smart Citation
“…There have however, been several reports of their presence in urine (Mandal et al, 2001;Valenzuela et al, 2005), although the analytical quality of these data has been questioned Slejkovec et al, 2008). It is worth noting that most studies on arsenic urine metabolites have failed to detect these reduced methylated species despite specific efforts to do so (e.g.…”
Section: Metabolismmentioning
confidence: 99%
“…It is worth noting that most studies on arsenic urine metabolites have failed to detect these reduced methylated species despite specific efforts to do so (e.g. Slejkovec et al, 2008). Thio-dimethylarsinate has been shown to be a urine metabolite from Bangladeshi women (Raml et al, 2007) and the suggestion was that this species may previously have been misidentified as dimethylarsinite.…”
Section: Metabolismmentioning
confidence: 99%
“…In their case the "missing" arsenic was retained 181 after lowering the pH via an injection of 100 µL of a 3 mol L -1 HCl solution. [21] Naramandura and Suzuki…”
mentioning
confidence: 99%
“…Avec une chromatographie liquide de paire d'ions il est possible de ré-duire considérablement la durée de l'analyse, la séparation des espèces est réalisée en 3 minutes et semble bien adaptée à des dosages en série [18]. Après séparation chromatographique, les dérivés arséniés sont analysés par spectromé-trie d'absorption atomique [19][20][21] ou par ICP-MS [13][14][15][16][17][18]. La génération d'hydrures a également été utilisée avec succès pour séparer As III , As V , MMA V et DMA V , le dosage de l'arsenic étant effectué par ICP-MS [22].…”
Section: Discussionunclassified