2019
DOI: 10.1109/tasc.2019.2904668
|View full text |Cite
|
Sign up to set email alerts
|

Analysis on Coordination of Over-Current Relay Using Voltage Component in a Power Distribution System With a SFCL

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…In this study, a new application of waveletbased artificial neural networks that overcome this shortcoming is presented [16]. In another study on SFCL, a stochastic approach is presented for evaluating transient recovery voltages induced along the Circuit Breaker poles of the simple test line equipped with SFCL [17].In a similar study, a method has been proposed that uses the voltage component as the effective parameter of the overcurrent protection relay to protect the power distribution system with SFCL [11]. In a study to analyze the effectiveness of SFCL, the applicability of different SFCLs in the voltage source converter based DC system according to the transient characteristics of the dc failure has been analyzed [18].…”
Section: Related Workmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, a new application of waveletbased artificial neural networks that overcome this shortcoming is presented [16]. In another study on SFCL, a stochastic approach is presented for evaluating transient recovery voltages induced along the Circuit Breaker poles of the simple test line equipped with SFCL [17].In a similar study, a method has been proposed that uses the voltage component as the effective parameter of the overcurrent protection relay to protect the power distribution system with SFCL [11]. In a study to analyze the effectiveness of SFCL, the applicability of different SFCLs in the voltage source converter based DC system according to the transient characteristics of the dc failure has been analyzed [18].…”
Section: Related Workmentioning
confidence: 99%
“…The SFCL is one of the methods used to control power fluctuations of micro grids in case of failure. In SFCL, there is no power loss during normal sensing time and provides rapid limiting operation within a quarter cycle without additional sensing device [11]. In order to minimize the damage caused by symmetrical and asymmetrical faults that may occur in power systems to loads, transmission lines and its components, the smart grid architecture that can operate in island mode with correct protection schemes is required.…”
Section: Introductionmentioning
confidence: 99%
“…Lim et al [8] have offered R-SFCL coordination with overcurrent relay, in this work overcurrent relay is used as voltage component and reduced the relay tripping time here they concentrate only relay time limiting, not concentrating on the stability.…”
Section: Literature Reviewmentioning
confidence: 99%
“…On the other hand, the second strategies focus on improving the protection systems to cope with the protection problems related to DG integration in the micro‐grids. In this regard, different measures are proposed consist of applying fault current limiters (FCLs) to improve the DG's fault ride‐through (FRT) capability, 9,10 using the new and programmable protection devices, 11‐13 proposing different protection schemes based on distance, differential or directional relays, 14‐18 and applying the communication systems for improving the performance of the protection systems 19,20 . While the first strategies can solve the protection issues, it may bring adverse impacts on the performance of the power system.…”
Section: Introductionmentioning
confidence: 99%