2020 International Electronics Symposium (IES) 2020
DOI: 10.1109/ies50839.2020.9231722
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the Effect of Cooling Water Condenser to Power Plant Cycle Using Cycle-Tempo Software

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 4 publications
0
9
0
Order By: Relevance
“…This has been conveyed in previous studies where the occurrence of backflow indicates a low heat transfer rate that occurs [8]. So it can be concluded that adding VG type common flow up and common flow down can delay the occurrence of backflow in the downstream tube.…”
Section: The Effect Of Vortex Generator On Velocity Contour and Temperature Contourmentioning
confidence: 57%
See 1 more Smart Citation
“…This has been conveyed in previous studies where the occurrence of backflow indicates a low heat transfer rate that occurs [8]. So it can be concluded that adding VG type common flow up and common flow down can delay the occurrence of backflow in the downstream tube.…”
Section: The Effect Of Vortex Generator On Velocity Contour and Temperature Contourmentioning
confidence: 57%
“…Research that discusses the effect of fuel changes on the performance of power plants [6,7]. Then there is also research that discusses the investigation of water cooling condensers and their impact on power plants [8].…”
Section: Introductionmentioning
confidence: 99%
“…The main data validated in each component are thermal data regarding temperature (T), enthalpy (h), pressure (P), and mass flow rate (m). These simulation results are quite acceptable when compared with similar studies using Cycle Tempo [18]. The actual power plant data is taken when the power plant is working at a load of 180 MW.…”
Section: A Validationmentioning
confidence: 67%
“…Trisnayanti et al [7] and Satrio et al [8], researched the fuel side, where the research aimed to determine the effect of fuel replacement on performance and fuel consumption in a steam power plant. Kurniawati et al [9], researched one of the main components in the power plant, the condenser. This research aims to determine the performance of the condenser and the efficiency of the power plant cycle, which is influenced by the temperature and flow rate of the cooling water.…”
Section: Introductionmentioning
confidence: 99%