2016
DOI: 10.24931/2413-9432-2016-5-1-3-8
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of photoluminescence decay kinetics of aluminum phthalocyanine nanoparticles interacting with immune cells

Abstract: Работа посвящена исследованию кинетики фотолюминесценции коллоидных растворов молекулярных нанокристаллов фталоцианина алюминия при различных pH и при взаимодействии с иммунокомпетентными клетками (макрофагами). Изучение кинетики проводилось при помощи системы регистрации, основанной на стрик-камере с пикосекундным разрешением (до 15 пс) C10627-13 Hamamatsu Photonics, сопряженной с волоконно-оптическим спектрометром, при пикосекундном лазерном возбуждении. В ходе эксперимента было зафиксировано изменение кинет… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Firstly, the surface molecules detached from the surface-thus, some nanoparticles disperse into the molecules. Secondly, it makes some surface molecules turn perpendicular to the surface of the nanoparticle [20] (more details are provided in the discussion section of this article). Additional activation allows the reduction of the time for FD of the tooth enamel.…”
Section: Research Resultsmentioning
confidence: 99%
“…Firstly, the surface molecules detached from the surface-thus, some nanoparticles disperse into the molecules. Secondly, it makes some surface molecules turn perpendicular to the surface of the nanoparticle [20] (more details are provided in the discussion section of this article). Additional activation allows the reduction of the time for FD of the tooth enamel.…”
Section: Research Resultsmentioning
confidence: 99%
“…The system works on a time-correlated single photon counting approach. The description of the system is reported in the [29]. The fiber was fixed on a tripod to maintain the working distance between the distal end and the tumor tissue.…”
Section: Methodsmentioning
confidence: 99%
“…For the evaluation of luminescence lifetime of PS the Hamamatsu streak-camera with a time-resolution was used [28]. It comprised a laser source Picosecond Light Pulser PLP-10 (Japan) with fiber optic output generating at the wavelength of 637 nm with a pulse duration of 65 ps and a polychromator with fiber optic input and Semrock optical filter LD 01-785/10-12.5 inlet that transmits only the spectral region of luminescence band of bacteriochlorins and minimized the impact of third-party flashes.…”
Section: Methodsmentioning
confidence: 99%