2021
DOI: 10.31258/ijeepse.4.3.173-178
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Peak Power Capacity on Rooftop Solar PV 1.25 kWp at Sun Conditions 90 Degrees

Abstract: This paper describes the optimization of energy conversion when solar radiation occurs at peak power conditions, namely at 11.00 am to 2.00 pm where the position of the sun is parallel to the layout of the PV Rooftop installation. The panels used are 5 units with the type of polycrystalline with a capacity of 1 panel unit consisting of 250 Wp. The position of the panels installed on the roof of the Andalas University building is based on an angle of 90o degrees with a position of ±255m above sea level. The adv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 13 publications
0
1
0
Order By: Relevance
“…In addition, it can be used successfully even when the systems do not have a clearly stated electric power capacity. In solar photovoltaic (PV) systems, a peak capacity (at standard test conditions) is available [34][35][36][37]; thus, a power-normalized metric may be used in such cases as kWh/kWp, which means the amount of electric energy generation (in kWh, kilowatt hours) per unit peak capacity power (in kWp, kilowatt peak). However, concentrated solar power systems do not have an equivalent well-defined instantaneous peak capacity power, but they still have well-defined accumulated electric energy generated over one year and a well-defined ground area.…”
Section: Goal Of the Studymentioning
confidence: 99%
“…In addition, it can be used successfully even when the systems do not have a clearly stated electric power capacity. In solar photovoltaic (PV) systems, a peak capacity (at standard test conditions) is available [34][35][36][37]; thus, a power-normalized metric may be used in such cases as kWh/kWp, which means the amount of electric energy generation (in kWh, kilowatt hours) per unit peak capacity power (in kWp, kilowatt peak). However, concentrated solar power systems do not have an equivalent well-defined instantaneous peak capacity power, but they still have well-defined accumulated electric energy generated over one year and a well-defined ground area.…”
Section: Goal Of the Studymentioning
confidence: 99%
“…Once the environment is defined, a value can be assigned to exergy in terms of the property values for the system only, such that exergy can be considered an extensive property of the system [1]- [3]. Exergy analysis is a thermodynamic analysis technique based on the second law of thermodynamics that provides an alternative and enlightening method for rational and meaningful assessment and comparison processes and systems [4], [5]. In particular, exergy analysis yields efficiency, which provides a true measure of how close to ideal performance is, and identifies the causes and locations of thermodynamic losses more clearly than energy analysis [6], [7].…”
Section: Introductionmentioning
confidence: 99%
“…The West Sumatra region has the potential for large-scale solar panel development as well as for household scale. This is influenced by the high potential for solar radiation with an average capacity of 4.8 kWh/m2 per day [14]. However, the frequent occurrence of rotating power outages have a significant impact on activities that occur in the local community such as the Bonjol area where this area does not yet have a main substation and is only supplied by the Bukit Tinggi and West Pasaman substations, even though the weather conditions in the Bonjol area are almost at sunlight reaches 12 hours with hot weather conditions [15].…”
Section: Introductionmentioning
confidence: 99%