2018
DOI: 10.1155/2018/4989584
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Isolation Ground Vibration by Graded Wave Impeding Block under a Moving Load

Abstract: Combined with the coordinate transformation, the dynamic governing equations for elastic foundation under a moving load are established by using the reverberation ray matrix method, and the isolation effect of a graded wave impeding block is studied. The displacement and the stress are obtained in the time domain by using numerical inverse Fourier transformation. Via numerical examples, the effectiveness of vibration isolation of graded wave impeding block is compared to conventional single phase solid homogen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…Besides, Jiang et al [46] found that WIB could achieve better performance in layered ground but the increased depth of stiffened block has little effect on the improvement of the performance, which should be considered in the design period. It was found that WIB can suppress the ground vibrations between 6 and 8 dB in a low-frequency range (<30 Hz) [47,48].…”
Section: Wave Impeding Blocksmentioning
confidence: 99%
“…Besides, Jiang et al [46] found that WIB could achieve better performance in layered ground but the increased depth of stiffened block has little effect on the improvement of the performance, which should be considered in the design period. It was found that WIB can suppress the ground vibrations between 6 and 8 dB in a low-frequency range (<30 Hz) [47,48].…”
Section: Wave Impeding Blocksmentioning
confidence: 99%
“…Most of the materials of WIB in the above studies are relatively single, and the materials are mainly concentrated in single-phase solid media, and there is less research on the composite mode of WIB and non-uniform materials. Ma (2018), Ma et al (2017) established a ground vibration isolation system with a functional gradient WIB in an elastic ground, and the study showed that the gradient WIB can effectively reduce the vibration amplitude. Gao et al (2020Gao et al ( , 2021 proposed a joint vibration isolation method combining Duxseal industrial filler and WIB (referred to as DXWIB), and found that the DXWIB barrier enhanced the bandwidth of traditional homogeneous WIB vibration reduction through experimental studies.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, to improve the vibration isolation performance of the conventional WIB for the above problems, some scholars carried out improvement on it. Ma et al 21,22 analyzed the vibration isolation effect of graded non-homogeneous WIB in elastic and saturated foundations under moving loads. Tian et al 23 based on the 2D semi-analytical BEM, the vibration isolation effect of Duxseal material in a 2D homogeneous elastic foundation with active vibration isolation are investigated.…”
Section: Introductionmentioning
confidence: 99%