2016
DOI: 10.1016/j.jvs.2016.04.053
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of endovascular therapy for femoropopliteal disease with the Supera stent

Abstract: Stenting of the superficial femoral and popliteal arteries using the Supera stent system appears to be safe and effective. The interwoven stent design may better serve areas under extreme mechanical stress. Our results with this population of highly diseased patients including very long lesion lengths are consistent with outcomes of other publications reporting the use of this device.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…After being acquired by Abbott in 2013, it gradually gained local popularity. The usage of interwoven helical stent increased in our cohort especially after several clinical studies, 7–13 including one local cohort study demonstrating the feasibility and acceptable result in elderly patients 8 …”
Section: Discussionmentioning
confidence: 91%
“…After being acquired by Abbott in 2013, it gradually gained local popularity. The usage of interwoven helical stent increased in our cohort especially after several clinical studies, 7–13 including one local cohort study demonstrating the feasibility and acceptable result in elderly patients 8 …”
Section: Discussionmentioning
confidence: 91%
“…Newer stents, with different radial strength and flexibility, have been developed for use in areas with extreme mobility demands, but they are still undergoing long-term assessment. 27 We consider that patients with involvement of the popliteal artery in the joint region are candidates for open surgery.…”
Section: Discussionmentioning
confidence: 99%
“…Lastly, although this analysis reviewed various technologies, including percutaneous transluminal angioplasty, drug‐coated balloon angioplasty, bare‐metal stent, and directional atherectomy, other technologies such as stent‐grafts, drug‐eluting stent, and other atherectomy devices were unavailable for analysis. This limitation is relevant since evidence exists that even within these classes of devices, differences may exist among devices, for example, interwoven nitinol stents versus laser‐cut hypotube stents, and drug‐coated balloons of different drug compositions and excipient formulations . Thus, it is possible that these devices may exhibit distinct patterns of restenosis.…”
Section: Discussionmentioning