2016
DOI: 10.1097/id.0000000000000381
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Effectiveness of Different Rotational Instruments in Implantoplasty

Abstract: All tested rotatory instruments performed the same level of surface roughness in the implantoplasty. The tungsten carbide bur caused a minor change in the implant temperature. The multilaminar bur performed a faster wear time. More in vivo studies are necessary to conclude which is the best rotatory instrument for implantoplasty.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
35
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(38 citation statements)
references
References 22 publications
2
35
0
Order By: Relevance
“…Kappa scores regarding agreement on the articles to be included in the full‐text analysis and those finally chosen were 0.91 and 0.95, respectively ( p < 0.001). Out of a total of 391 records assessed, 26 publications were finally included: six laboratory (Chan et al, ; Costa‐Berenguer et al, ; Gehrke, Aramburú Júnior, Dedavid, & Shibli, ; Sharon, Shapira, Wilensky, Abu‐Hatoum, & Smidt, ; de Souza Júnior et al, ; Tribst, Piva, Shibli, Borges, & Tango, ), two preclinical in vivo (Schwarz, Mihatovic, Golubovic, Becker, & Sager, ; Schwarz, Sahm, Mihatovic, Golubovic, & Becker, ), and 18 clinical publications (Englezos, Cosyn, Koole, Jacquet, & De Bruyn, ; Geremias et al, ; Matarasso et al, ; Nart, de Tapia, Pujol, Pascual, & Valles, ; Pommer et al, ; Ramanauskaite, Becker, Juodzbalys, & Schwarz, ; Romeo et al, ; Sapata, de Souza, Sukekava, Villar, & Neto, ; Schwarz et al, ; Schwarz, John, & Becker, ; Schwarz, John, Mainusch, Sahm, & Becker, ; Schwarz, John, Sahm, & Becker, ; Schwarz, John, Schmucker, Sahm, & Becker, ; Schwarz, Sahm, & Becker, ; Schwarz, Sahm, Iglhaut, et al, ; Suh, Simon, Jeon, Choi, & Kim, ; Thierbach & Eger, ). The two preclinical in vivo publications (Schwarz, Mihatovic, et al, ; Schwarz, Sahm, Mihatovic, et al, ) and the clinical of Romeo et al () and Romeo et al () publications reported on different aspects basically of the same study population.…”
Section: Resultsmentioning
confidence: 99%
“…Kappa scores regarding agreement on the articles to be included in the full‐text analysis and those finally chosen were 0.91 and 0.95, respectively ( p < 0.001). Out of a total of 391 records assessed, 26 publications were finally included: six laboratory (Chan et al, ; Costa‐Berenguer et al, ; Gehrke, Aramburú Júnior, Dedavid, & Shibli, ; Sharon, Shapira, Wilensky, Abu‐Hatoum, & Smidt, ; de Souza Júnior et al, ; Tribst, Piva, Shibli, Borges, & Tango, ), two preclinical in vivo (Schwarz, Mihatovic, Golubovic, Becker, & Sager, ; Schwarz, Sahm, Mihatovic, Golubovic, & Becker, ), and 18 clinical publications (Englezos, Cosyn, Koole, Jacquet, & De Bruyn, ; Geremias et al, ; Matarasso et al, ; Nart, de Tapia, Pujol, Pascual, & Valles, ; Pommer et al, ; Ramanauskaite, Becker, Juodzbalys, & Schwarz, ; Romeo et al, ; Sapata, de Souza, Sukekava, Villar, & Neto, ; Schwarz et al, ; Schwarz, John, & Becker, ; Schwarz, John, Mainusch, Sahm, & Becker, ; Schwarz, John, Sahm, & Becker, ; Schwarz, John, Schmucker, Sahm, & Becker, ; Schwarz, Sahm, & Becker, ; Schwarz, Sahm, Iglhaut, et al, ; Suh, Simon, Jeon, Choi, & Kim, ; Thierbach & Eger, ). The two preclinical in vivo publications (Schwarz, Mihatovic, et al, ; Schwarz, Sahm, Mihatovic, et al, ) and the clinical of Romeo et al () and Romeo et al () publications reported on different aspects basically of the same study population.…”
Section: Resultsmentioning
confidence: 99%
“…6,26,27 Other studies have included rough and smooth diamond burs as well as carbide and silicon burs with various sequences. 6,17,18,19 de Souza et al 19 , demonstrated that three different rotational instruments: diamond, tungsten carbide and multilaminar burs resulted in similar surface roughness after performing implantoplasty procedures. However, the results from this study did not objectively standardised the time of instrumentation as it was determined by visual analysis of the operator only.…”
Section: A B C Dmentioning
confidence: 99%
“…7,17 This involves mechanically adjusting the exposed implant threads with rotary instruments to reduce the roughness of the surface and therefore minimise future plaque retention. 17,18,19,20 Although it is well accepted that the affected rough implant surface must be altered to minimise the establishment of biofilm, there is no current consensus in the literature regarding a suitable polishing protocol.…”
Section: Introductionmentioning
confidence: 99%
“…The patient signed an informed consent and 3 different treatments were proposed:Implantoplasty (at the area of implant 36) was performed according to the Schwarz et al protocol [9, 10]. …”
Section: Case Reportmentioning
confidence: 99%
“…Implantoplasty (at the area of implant 36) was performed according to the Schwarz et al protocol [9, 10]. …”
Section: Case Reportmentioning
confidence: 99%