2014
DOI: 10.1088/1009-0630/16/8/01
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Performance of the Thomson Scattering Diagnostics on HT-7 Tokamak Based on I-EMCCD

Abstract: A visible light imaging Thomson scattering (VIS-TVTS) diagnostic system has been developed for the measurement of plasma electron temperature on the HT-7 tokamak. The system contains a Nd:YAG laser (λ = 532 nm, repetition rate 10 Hz, total pulse duration ≈ 10 ns, pulse energy > 1.0 J), a grating spectrometer, an image intensifier (I.I.) lens coupled with an electron multiplying CCD (EMCCD) and a data acquisition and analysis system. In this paper, the measurement capability of the system is analyzed. In additi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 8 publications
(6 reference statements)
0
5
0
Order By: Relevance
“…Gaseous impurity injections were widely used on EAST for diagnostic purposes, for example, argon puffing was mainly used to measure ion temperature and plasma rotation by X-ray crystal spectrometer (XCS) [13−15] . Nitrogen was injected for the calibration of the Thomson scattering (TS) diagnostic system [16,17] .…”
Section: Methodsmentioning
confidence: 99%
“…Gaseous impurity injections were widely used on EAST for diagnostic purposes, for example, argon puffing was mainly used to measure ion temperature and plasma rotation by X-ray crystal spectrometer (XCS) [13−15] . Nitrogen was injected for the calibration of the Thomson scattering (TS) diagnostic system [16,17] .…”
Section: Methodsmentioning
confidence: 99%
“…It shows that the relative gain increases with DAC and varies in the range of 1-367, and the maximum relative error in the multiple measurements is about 7%. The voltage of 6 kV between MCP125 and P43 phosphor screen provides the generation of 240 photons for every incident electron emitted from the MCP [10]. Overall speaking, the number of photons finally exiting the intensifier is:…”
Section: Performance Assessmentmentioning
confidence: 99%
“…TV Thomson scattering (TVTS) system based on TS principle is a promising technique for the measurements of edge electron temperature and density with high spectral resolution , which has previously been installed on the TEXTOR [9], HT-7 [10], and so on [11,12]. In contrast to the conventional TS system, the equipping of grating spectrometer and camera detectors make the TVTS system have the advantages of multipoint and high-precision spectral measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Electron temperature and density is measured by Thomson scattering diagnostics. [21] Since the measured intensity of bremsstrahlung is presented by the counting rate of photons, equation (1) can be changed into…”
Section: Absolute Intensity Calibration Of Euv Spectrometermentioning
confidence: 99%