2018
DOI: 10.1109/jestpe.2017.2759810
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Measures of Ultralow-Frequency Oscillations in a Large-Scale Hydropower Transmission System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
17
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 48 publications
(21 citation statements)
references
References 18 publications
0
17
0
Order By: Relevance
“…Yang and Yang and Zhao and Ren also studied the role of pumped storage units in enhancing power system stability and frequency control [7,8]. It can be seen from some accidents in the power system that the units with the input of primary frequency regulation function and the correct setting of primary frequency regulation parameters can greatly restrain the expansion of the accident and ensure the stability of the power system [9][10][11]. e pumped storage unit regulation system (PSURS) has strong nonlinear and time-varying characteristics [12], and PSU has "S" characteristic area, which leads to the frequency oscillation of the unit under low water head [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Yang and Yang and Zhao and Ren also studied the role of pumped storage units in enhancing power system stability and frequency control [7,8]. It can be seen from some accidents in the power system that the units with the input of primary frequency regulation function and the correct setting of primary frequency regulation parameters can greatly restrain the expansion of the accident and ensure the stability of the power system [9][10][11]. e pumped storage unit regulation system (PSURS) has strong nonlinear and time-varying characteristics [12], and PSU has "S" characteristic area, which leads to the frequency oscillation of the unit under low water head [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…It was concluded that the turbine and governing system would produce negative damping and weaken the stability of the system. Especially, differing from thermal units, the hydropower units' water hammer effect plays a negative role in ultra-low frequency band [8]- [13]. Furthermore, the influences of different governor control modes and governor parameters on damping torque were analyzed.…”
Section: Introductionmentioning
confidence: 99%
“…In 2016, an extremely low frequency oscillation (about 0.05 Hz) occurred in China Southern Power Grid during asynchronous testing [2]. Simulation indicates that the parameters of governors may lead to substantial effects [3]. An ultra-low frequency eigenmode with 0.08 Hz was motivated in the second stage of the north Brazil blackout in 2018 [4].…”
Section: Introductionmentioning
confidence: 99%