2009
DOI: 10.2172/983689
|View full text |Cite
|
Sign up to set email alerts
|

Analyses to support development of risk-informed separation distances for hydrogen codes and standards.

Abstract: The development of a set of safety codes and standards for hydrogen facilities is necessary to ensure they are designed and operated safely. To help ensure that a hydrogen facility meets an acceptable level of risk, code and standard development organizations are utilizing risk-informed concepts in developing hydrogen codes and standards.This report describes the application of a risk-informed process to establish one code requirement: the separation distances between a bulk gaseous hydrogen storage facility a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
63
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 42 publications
(71 citation statements)
references
References 18 publications
0
63
0
1
Order By: Relevance
“…NFPA 2 selected a fatality risk guideline of 2×10 −5 /yr for members of the public for use in the separation distance work documented in [7]. This value is consistent with the risk at existing gasoline stations, is in general agreement with criteria being utilized in several countries, and is approximately twice the value recommended by European Industrial Gas Association (EIGA) for hydrogen facilities.…”
Section: Unacceptable Risk Thresholdmentioning
confidence: 53%
See 3 more Smart Citations
“…NFPA 2 selected a fatality risk guideline of 2×10 −5 /yr for members of the public for use in the separation distance work documented in [7]. This value is consistent with the risk at existing gasoline stations, is in general agreement with criteria being utilized in several countries, and is approximately twice the value recommended by European Industrial Gas Association (EIGA) for hydrogen facilities.…”
Section: Unacceptable Risk Thresholdmentioning
confidence: 53%
“…A risk-informed approach had previously been used to establish the separation distances for bulk gaseous hydrogen storage areas [6,7]. The goal of the current work was to extend this approach in a way that could be used to inform codes and standards for indoor fueling, and to provide an initial assessment of fatality risks for a generic system.…”
Section: Objectivesmentioning
confidence: 99%
See 2 more Smart Citations
“…Although some work has been done to define leak probabilities and credible leak sizes (LaChance et al 2009), more work is needed.…”
Section: Preventing or Mitigating The Potential Hazardsmentioning
confidence: 99%